4 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 5
SECTION 3 |
Display
• Press ON/OFF Button (1 in Fig 2.1) to Switch OFF the Inverter: The LCD
Display (2 in Fig 2.1) will switch OFF. However, the Inverter will not switch
OFF and the batteries will continue to drain due to the following energy
consumption:
(i) Due to the “no load draw” of the inverter if no load is present or due
to the DC side current draw if AC load is present
(ii) Due to the power drawn by the fans (the fans in the Inverter run
continuously as long as the inverter is in ON condition)
2. LCD display
3. (Not shown. Located at the back of the Remote). 8P8C (8 Position, 8 Conductor)
Modular Connector Receptacle (also known as RJ-45 Receptacle) used for
connecting the Remote Control to the Inverter with the help of 10', Cat 5, 8
conductor cable.
3.1 DISPLAY
A Green backlit LCD display is used to display operational parameters and fault
conditions. Details of information displayed are shown at Fig 3.1 below:
The backlighting has 2 intensities
of brightness – dim and bright:
• When the inverter is supplying
no power (is in no load condi-
tion) or lower power below the
minimum power display thresh-
old of 50W to 100W, the bar
graph will NOT be displayed.
Also, the back-light will be dim
• When the power supplied
is more than the minimum
power display threshold of
50W to 100W, the 1st bar will
appear and the back-light will
brighten. More number of bars
will be displayed proportional
to power output level.
Fig. 3.1 Details of LCD Screen