5.5.3 Adjusting and setting the automatic depth control valve block
NOTE!!!
The valve block has been set to the proper pressure and flow at the factory.
WARNING!!!
When performing maintenance on the hydraulic system of the SAMON Haulm Topper, make sure that
there is no pressure on the system.
Always remove the hydraulic hoses before maintenance.
A:
Set the valve block pressure.
B:
Set the valve block flow.
C:
Connection point for pressure measurement.
D:
Vent connection point.
To ensure maximum performance of the automatic depth control, it will be necessary to adjust the valve block
as follows after repair or maintenance.
Value:
Adjustment:
Flow:
Max 30 L/min
Turn the knob to close the flow control valve
, then open by 1 ¼
turn
and secure the locking pin.
Pressure:
Max. 120 bar
Measure using a manometer connected to the measuring point
(yellow cap). After setting, retighten the lock nut.