![Samoa LARIUS VIKING Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/samoa/larius-viking/larius-viking_operating-and-maintenance-manual_3965231014.webp)
www.larius.com
12
VIKING
ED. 03 - 09/2020 - Cod. 150163
WARNING :
If the equipment is still under pressure after performing the operations above described because of the nozzle
or the flexible hose clogged, proceed as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product and press the trigger to release pressure.
• Loosen very slowly the fitting of connection from the flexible hose to the gun.
• Clean or replace the flexible hose and the nozzle.
CORRECT PROCEDURE OF DECOMPRESSION
• Insert the gun clamp
(N1)
.
• Move the
ON/OFF
switch
(N2)
to the
OFF
position
(0)
to
stop the equipment.
• Disconnect the power supply cable
(N3)
.
• Release the gun clamp
(N4)
. Point the gun at the tank of the
product and press the trigger to release pressure. At the end
of the operation, insert the gun clamp.
• Open the re-circulation valve
(N5)
to release residual pressure.
OFF
0
N5
N2
N1
N3
N4
N
Fig. 1N
Fig. 2N
Fig. 3N
Fig. 4N
Содержание LARIUS VIKING