Fig. 1J
GROUNDING OF THE GENERATOR
J
An improper grounding may produce thick mists
of paint that may represent a risk of intoxication
for the personnel and an inadequate coating
(
pattern will not shape, deformed pattern, wrap
back effect, etc..
).
To avoid these inconveniences, make sure that
all system components are properly grounded.
Never use non-conductive tools and/or tanks
made of plastic or wood.
GROUNDING
The optimal condition to achieve perfect coating and complete
safety for the personnel is the proper grounding of all system
components. In particular, make sure that:
• All system components are duly grounded.
• The hook holding the piece to be coated is perfectly clean.
• Tubes and grounding cables are not damaged. Should they
be worn, provide for their replacement.
FOR CONNECTION BETWEEN PUMP, FLEXIBLE HOSE AND
SPRAY GUN BEFORE USING THE EQUIPMENT.
• ALWAYS USE THE FLExIBLE HOSE SUPPLIED WITH STAN
-
DARD KIT.
• THE USE OF ANY ACCESSORIES OR TOOLING OTHER THAN
THOSE RECOMMENDED IN THIS MANUAL, MAY CAUSE
DAMAGE OR INJURE THE OPERATOR.
• THE FLUID CONTAINED IN THE FLExIBLE HOSE CAN BE VERY
DANGEROUS. HANDLE THE FLEXIBLE HOSE CAREFULLY. DO
NOT PULL THE FLExIBLE HOSE TO MOVE THE EQUIPMENT.
NEVER USE A DAMAGED OR A REPAIRED FLExIBLE HOSE.
The high speed of travel of the product in the hose
can create static electricity through discharges
and sparks. It is suggested to earth the equipment.
The pump is earthed through the earth cable of
the supply.
The gun is earthed through the high pressure
flexible hose.
All the conductors near the work area must be
earthed.
Avoid approaching too much to the pump piston
rod when the pump is working or under pressure.
A sudden movement of the piston rod can cause
wounds or finger squashing.
Never spray over flammable products or solvents
in closed places.
Never use the tooling in presence of potentially
explosive gas.
Always check that the product is compatible with
the materials composing the equipment (
pump,
spray gun, flexible hose and accessories
) with
which it can come into contact. Never use paints
or solvents containing Halogen Hydrocarbons
(
as the Methylene Chloride
). If these products
come into contact with aluminium parts can
provoke dangerous chemical reactions with risk
of corrosion and explosion.
If the product to be used is toxic, avoid inhalation
and contact by using protection gloves, goggles
and proper face shields.
Take proper safety measures for the protection
of hearing in case of work near the plant.