CORRECT PROCEDURE OF
DECOMPRESSION
Clamp inserted
Clamp released
O1
Fig.1O
O2
Fig.2O
Fig.3O
O3
O4
Fig.4N
Fig.5O
O5
Open
Miro' for sanitation
• Release the gun clamp (
O1
). Point the gun at the tank of the
product and press the trigger to release pressure. At the end
of the operation, insert the gun clamp.
• Open the re-circulation tap (
O5
) to release residual pressure.
• Insert the gun clamp (
O1
).
• Disconnect the power supply cable (
O4
).
• Move the ON/OFF switch (
O2
) to the
OFF position (0)
to
stop the equipment.
• Set the valve (
O3
) at its minimum pressure setting (turn
anticlockwise).
WARNING
:
If the equipment is still under pressure after
performing the operations above described
because of the nozzle or the flexible hose
clogged, proceed as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product
and press the trigger to release pressure.
• Loosen very slowly the fitting of connection
from the flexible hose to the gun.
• Clean or replace the flexible hose and the
nozzle.