Problem
Possible cause
Solution
The pump does not start
Feed air not sufficient;
Check on the air supply line. Increase
the diameter of the feed hose;
Outlet product line clogged;
Open the recirculation tap to check
whether the pump starts up. Unscrew
the high pressure filter and clean/replace
the filter sieve. Clean/replace the spray
gun’s filter.
Clogged product intake line;
Clean the suction filter;
Pneumatic motor blocked in the cycle
reversal position;
Reduce feed air pressure;
Disassemble the motor and verify;
There is no product;
Add the product;
Accelerate working and no pressure
of the pump
The pump sucks air;
Check the flexible suction tube;
Gaskets of the pumping rod worn;
Replace the lower gaskets;
Suction valve worn or partially clogged;
Disassemble the suction valve. Clean
and/or replace, if possible, the parts
worn;
Suction filter clogged;
Clean/replace the suction filter’s two
disks;
Suction filter too fine;
Remove the fine disk, leaving only the
larger one inside;
Gaskets of the pumping rod worn;
Replace the lower seals
The pump functions, but doesn’t stop
when the chamber is full (the pump
continues slowly, increasing and/or
decreasing)
Suction valve worn or partially clogged;
Disassemble the suction valve. Clean
and/or replace, if possible, the parts
worn;
Delivery valve worn or partially obstructed;
Remove the delivery valve and clean/
replace any worn parts;
Upper gaskets worn.
Tighten the packing nut.
The pressure of the material is si-
gnificantly reduced when the trigger
is pressed
The spray gun’s nozzle is too large or worn
Replace it with a smaller one
The spray gun’s filter and the material
output filter’s sieve are too fine
Replace them with filters of a larger
mesh size