![Samoa Larius 2 Transfer Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/samoa/larius-2-transfer/larius-2-transfer_operating-and-maintenance-manual_805322025.webp)
1
2
3
4
6
5
8
7
9
DESCRIPTION OF THE EQUIPMENT
Pos. Description
1
Pump feed air inlet
2
Exchange valve air supply pipe
3
Pump feed air manometer
4
Pump feed air pressure regulator
5
Pilot valve
Pos. Description
6
Pilot valve reset push button
7
Pump fastening and supporting bracket
8
Material inlet fitting
9
Material outlet filling
INSTALLATION
• Fix the pump on a base by using the supporting brackets holes.
NEVER INSTALL
the pump upside-down or inclined
CONNECTION TO THE REED AIR
• For pump feed use a hose with a internal diameter no lower than 6 mm.
SUCTION AND DELIVERY HOSES CONNECTION
• Connect the suction and delivery hoses to the pump it is suggested to tighten the fillings.
• Make sure the hoses are not too heavy for the pump structure
WASHING OF THE BRAND NEW EQUIPMENT
• The LARIUS 2 pump has been tested at our plant with light mineral oil left inside of the pumping elementi ad protection.
Before sucking the product, carry out a washing using a diluent.
• The suction hose diameter must be proper to the viscosity of the fluid to be pumped. The installation of a filer at the end of
the suction hose is recommended
.
WORKING
• Dip the suction hose into the tank of the product.
• Let compressed air flow to the pump. Adjust air pressure to the minimum level necessary to the working of the pump
continually
• The pump will start and sto when all the product chamber will be full. Each time the delivery valve is open, the pump will
start again to work.
SETTING-UP
Check all the connection fittings of the com-
ponents
(pump. flexble hose, etc.)
before using
the equipment.
Avoid pump iding because it could damage the
pneumatic system and the membranes.
EN
www.larius.com
25
LARIUS 2 TRANSFER
ED.
10 - 01/2022 - Cod. 150146
G
H
I
Fig. 1G
Fig. 2G