The table below provides the meaning of the symbols used in this manual in relation to using, earthing, operating, maintaining, and 
repairing of this equipment.

WARNINGS

• Read this operator’s manual carefully before using the equipment.

• An improper use of this machine can cause injuries to people or things.

• Do not use this machine when under the influence of drugs or alcohol.

• Do not modify the equipment under any circumstances.

• Use products and solvents that are compatible with the various parts of the equipment, and read the manufacturer’s warnings carefully.

• See the Technical Details for the equipment given in the Manual.

• Check the equipment for worn parts once a day.  If any worn parts are found, replace them using ONLY original spare parts.

• Keep children and animals away from work area.

• Comply with all safety standards.

• It indicates an accident risk or serious damage to equipment if this warning is not followed.

FIRE AND EXPLOSION HAZARD

• Solvent and paint fumes in work area can ignite or explode.

• 

To help prevent fire and explosion:

   - Use equipment ONLY in well ventilated area.

   - Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static arc).

   - Ground equipment and conductive objects.

   - Use only grounded hoses.

   -  Do not use trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in 

 

pressurized aluminium equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, 

serious injury, and property damage.

   - Do not form connections or switch light switches on or off if the air contains inflammable fumes.

•  If electrical shocks or discharges are encountered the operation being carried out using the equipment 

must be stopped immediately

.

• Keep a fire extinguisher at hand in the immediate vicinity of the work area.

• It indicates wound and finger squashing risk due to movable parts in the equipment.

• Keep away from moving parts.

• Do not use the equipment without the proper protection.

• Before any inspection or maintenance of the equipment, carry out the decompression procedure explained in this manual, and prevent any risk of the equipment 

starting unexpectedly.

• Report any risk of chemical reaction or explosion if this warning has not been given.

•  (IF PROVIDED) There is a risk of injury or serious lesion related to contact with the jet from the spray gun. If this should occur, IMMEDIATELY contact a doctor, 

indicating the type of product injected.

• (IF PROVIDED) Do not spray before the guard has been placed over the nozzle and the trigger on the spray gun.

• (IF PROVIDED) Do not put your fingers in the spray gun nozzle.

• Once work has been completed, before carrying out any maintenance, complete the decompression procedure.

•  It indicates important recommendations about disposal and recycling process of products in accordance with the environmental regulations.

•  Mark any clamps attached to earth cables.

•  Use ONLY 3-wire extension cords and grounded electrical outlets.

•  Before starting work make sure that the electrical system is grounded and that it complies with safety standards.

• High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin.

• 

 To help prevent injection, always:

 

  - (IF PROVIDED) Engage trigger lock when not spraying.

   - (IF PROVIDED) Do not put your hand over the spray tip. Do not stop or deflect leaks with your hand, body or other.

   - (IF PROVIDED) Do not point gun at anyone or at any part of the body.

   - (IF PROVIDED) Never spray without tip guard.

   - Do pressure relief if you stop spraying or being servicing sprayer and before any maintenance operations.

   - Do not use components  rated less than sprayer Maximum Working Pressure.

   - Never allow children to use this unit

   - (IF PROVIDED) Brace yourself; gun may recoil when triggered.

If high pressure fluid pierces your skin, the injury might look like “just a cut”, but it is a serious wound!  

Get immediate medical attention.

• It is obligatory to wear suitable clothing as gloves, goggles and face shield.

• Wear clothing that complies with the safety standards in force in the country in which the equipment is used.

• Do not wear bracelets, earrings, rings, chains, or anything else that may hinder the operator’s work.

• Do not wear clothing with wide sleeves, scarves, ties, or any other piece of clothing that could get tangled up in moving parts of the equipment during the work, 

inspection, or maintenance cycles.

EN

www.larius.com

21

LARIUS 2 TRANSFER

ED.

 10 - 01/2022 - Cod. 150146

A

Содержание Larius 2 Transfer

Страница 1: ... D USO E MANUTENZIONE OPERATING AND MAINTENANCE MANUAL IT LARIUS 2 Travaso pagina 4 EN LARIUS 2 Transfer page 20 IT EN IT http www larius org manuali LARIUS_2_T_I pdf EN http www larius org manuali LARIUS_2_T_UK pdf DE http www larius org manuali LARIUS_2_T_D pdf FR http www larius org manuali LARIUS_2_T_F pdf ES http www larius org manuali LARIUS_2_T_E pdf ...

Страница 2: ...ità di variare caratteristiche e dati del presente manuale in qualunque momento e senza preavviso LARIUS 2 Travaso A AVVERTENZE 3 B TRASPORTO E DISIMBALLAGGIO 4 C CONDIZIONI DI GARANZIA 4 D NORME DI SICUREZZA 4 E PRINCIPIO DI FUNZIONAMENTO 5 F DATI TECNICI 6 G DESCRIZIONE DELL APPARECCHIATURA 7 H MESSA A PUNTO 7 I FUNZIONAMENTO 7 J INCONVENIENTI E RIMEDI 8 K ELENCO RICAMBI LARIUS 2 IN ALLUMINIO 10...

Страница 3: ...ischio di avvio improvviso dell apparecchiatura Segnalano il rischio di reazioni chimiche e rischio di esplosione se non viene eseguito l avvertimento SE PREVISTA Esiste il pericolo di ferite o gravi lesioni causate dal contatto con il getto della pistola in tal caso ricorrere IMMEDIATAMENTE alle cure mediche specificando il tipo di prodotto iniettato SE PREVISTA Non spruzzare senza aver installat...

Страница 4: ...ALUTARE MAI UNA LESIONE PROCURATA DALL INIEZIONE DI UN FLUIDO TOGLIERESEMPREL ALIMENTAZIONEELETTRICAESCARICARE LA PRESSIONE NEL CIRCUITO PRIMA DI EFFETTUARE QUALSIASI TIPO DI CONTROLLO O DI SOSTITUZIONE DEI PARTICOLARI DELL APPARECCHIATURA NON MODIFICARE MAI NESSUN PARTICOLARE DELL APPARECCHIATURA VERIFICA REGOLARMENTE I COMPONENTI DEL SISTEMA SOSTITUIRE I PARTICOLARI DANNEGGIATI O USURATI STRINGE...

Страница 5: ...ono idrocarburi alogenati come il cloruro di metilene Questi prodotti a contattoconpartiinalluminiodell apparecchiatura possono causare pericolose reazioni chimiche con rischio di esplosione Evitare di avvicinarsi eccessivamente allo stelo pistone della pompa quando questa è in funzione o in pressione Un movimento improvviso o brusco dello stelo pistone può provocare lesioni o schaicciamenti alle ...

Страница 6: ...esente queste note quando si deve valutare la compatibilità di un prodotto da utilizzare e quando si vuole procedere all eliminazione di uno o più particolari della pompa non più utilizzabili ai fini di programmare il riciclaggio dei singoli componenti nel rispetto dell ambiente DATI TECNICI LARIUS 2 Pressione massima d esercizio 7 bar 100 psi Pressione aria di alimentazione pompa 1 7 bar 15 100 p...

Страница 7: ... il peso delle tubazioni non gravi eccessivamente sulla struttura della pompa LAVAGGIO DELL APPARECCHIATURA NUOVA La pompa è stata collaudata in fabbrica con olio minerale leggero che è rimasto all interno del pompante per protezione Prima di aspirare il prodotto bisogna eseguire un lavaggio con diluente FUNZIONAMENTO Immergere il tubo di aspirazione nel serbatoio del prodotto Far affluire l aria ...

Страница 8: ...otta Sostituire la membrana Valvola di pilottaggio bloccata Premere i pulsanti di ripristino posti ai lati della valvola La pompa ha un funzionamento accelerato e non va in pressione Manca il prodotto Aggiungere il prodotto La pompa aspira aria Aprire la valvola di spurgo Per la ver sione sul paranco vedere le istruzioni contenute nel manuale relativo Le sfere non chiudono perfettamente Smontare e...

Страница 9: ...P a g i n a l a s c i a t a i n t e n z i o n a l m e n t e v u o t a ...

Страница 10: ...4 11 10 27 26 25 19 20 22 21 3 2 4 35 36 47 48 24 23 20 19 18 1 6 5 2 34 33 21 22 20 19 23 24 25 26 28 28 29 31 31 30 32 27 46 42 41 40 39 38 37 43 44 45 29 IT elenco ricambi larius 2 in alluminio www larius com 10 LARIUS 2 TRAVASO ED 10 01 2022 Cod 150146 K ...

Страница 11: ...i membrana 4 20 301013 Anello OR 4 21 8013 Membrana PTFE 2 8187 Membrana PTFE per prodotti abrasivi 2 22 8014 Membrana gomma 2 Pos Codice Descrizione Q tà 23 8011 Rondella 2 24 8007 Anello elastico 2 25 8005 Anello OR 2 26 8004 Sede anello 2 27 8006 Anello 2 28 8021 Pattino 2 29 8009 Anello elastico 2 30 8010 Spina elastica 1 31 8043 Anello OR 2 32 8008 Asta 1 33 8001 Corpo pompa 1 34 8047 Vite 12...

Страница 12: ...9 31 43 42 48 47 45 4 3 2 11 41 14 16 15 32 43 42 7 47 45 12 13 46 45 40 39 38 37 36 26 25 24 23 22 18 10 21 20 10 9 8 3 2 4 1 6 5 2 33 34 35 17 19 28 IT elenco ricambi larius 2 in acciaio inossidabile www larius com 12 LARIUS 2 TRAVASO ED 10 01 2022 Cod 150146 L ...

Страница 13: ...embrana 2 19 8084 Vite 4 20 8013 Membrana PTFE 2 8187 Membrana PTFE per prodotti abrasivi 2 21 8014 Membrana gomma 2 22 8011 Rondella 2 Pos Codice Descrizione Q tà 23 8007 Anello elastico 2 24 8005 Anello OR 2 25 8004 Sede anello 2 26 8006 Anello 2 27 8021 Pattino 2 28 8009 Anello elastico 2 29 8010 Spina elastica 1 30 8043 Anello OR 2 31 8008 Asta 1 32 8001 Corpo pompa 1 33 8047 Vite 12 34 8054 S...

Страница 14: ... 13 11 11 1 9 12 12 13 13 11 11 8 2 8 7 6 11 11 10 10 12 12 11 11 8 8 1 1 2 10 3 9 2 2 3 3 10 40334 40331 40331 1 40335 IT KIT elenco ricambi larius 2 in aLLUMINIO INOX www larius com 14 LARIUS 2 TRAVASO ED 10 01 2022 Cod 150146 M ...

Страница 15: ...a 2 Cod KIT 40334 Sede sfera Sfere LARIUS 2 Pos Descrizione Q tà 1 Anello OR 4 2 Sfera sup Ø9 16 2 3 Sede sfera sup 2 9 Sede sfera inf 2 10 Sfera inf Ø3 4 2 Cod KIT 40335 Guarnizioni motore Pos Descrizione Q tà 4 Anello OR 2 5 Pattino 2 6 Anello 2 7 Anello OR 2 Cod KIT 40331 Membrane LARIUS 2 Pos Descrizione Q tà 8 Rondella 2 11 Anello OR 4 12 Membrana PTFE 2 13 Membrana gomma 2 www larius com 15 ...

Страница 16: ...mero di serie o numero di lotto xxxx PROGRESSIVO anno AA ZONA PERICOLOSA CATEGORIE SECONDO DIRETTIVA 94 9 CE Gas vapori o nebbie Zona 0 1G Gas vapori o nebbie Zona 1 2G oppure 1G Gas vapori o nebbie Zona 2 3G 2G oppure 1G Corrispondenze tra zone pericolose sostanze e categorie POMPE A MEMBRANA A BASSA PRESSIONE PER TRAVASO LARIUS SERIE 2 LARIUS SERIE 4 Rapporto di pressione 1 1 1 1 Pressione aria ...

Страница 17: ...iltrata e provenire da zona sicura SAFE AREA Prima dell installazione leggere attentamente quanto riportato nel manuale d uso e manutenzione Tutte le operazioni di manutenzione devono essere eseguite secondo quanto riportato nel manuale Le pompe pneumatiche a pistone serie VEGA non devono funzionare a vuoto Tutte le operazioni di installazione e manutenzione devono essere fatte da personale qualif...

Страница 18: ...IT www larius com 18 LARIUS 2 TRAVASO ED 10 01 2022 Cod 150146 ...

Страница 19: ...sabilità che il prodotto è conforme alle direttive Direttiva CE 2006 42 Direttiva Macchine nonchè alle seguenti norme armonizzate UNI EN ISO 12100 1 2 Sicurezza del macchinario concetti fondamentali principi generali di progettazione Terminologia di base metodologia Principi tecnici La presente dichiarazione riguarda esclusivamente il prodotto nello stato in cui è stato immesso sul mercato esclude...

Страница 20: ...ort services enabling you to achieve the results desired quickly and professionally Due to a constant product improvement program the factory reserves the right to modify technical details mentioned in this manual without prior notice EN LARIUS 2 Travaso A WARNINGS 3 B TRANSPORT AND UNPACKING 4 C CONDITIONS OF GUARANTEE 4 D SAFETY RULES 4 E WORKING PRINCIPLE 5 F TECHNICAL DATA 6 G DESCRIPTION OF T...

Страница 21: ...nd prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not been given IF PROVIDED There is a risk of injury or serious lesion related to contact with the jet from the spray gun If this should occur IMMEDIATELY contact a doctor indicating the type of product injected IF PROVIDED Do not spray before the guard has been placed o...

Страница 22: ... THE SUPPLY AND RELEASE THE PRESSURE IN THE CIRCUIT BEFORE PERFORMING ANY CHECK OR PART REPLACEMENT OF THE EQUIPMENT NEVER MODIFY ANY PART IN THE EQUIPMENT CHECK REGULARLY THE COMPONENTS OF THE SYSTEM REPLACE THE PARTS DAMAGED OR WORN IF PROVIDED TIGHTEN AND CHECK ALL THE FITTINGS FOR connection between pump flexible hose and spray Thedisposalofpackagingmaterialsisacustomer s competence and must b...

Страница 23: ... these products come into contact with aluminium parts can provoke dangerous chemical reactions with risk of corrosion and explosion Avoid approaching too much to the pump piston rod when the pump is working or under pressure A sudden movement of the piston rod can cause wounds or finger squashing If the product to be used is toxic avoid inhalation and contact by using protection gloves goggles an...

Страница 24: ...ar 100 psi Pump freed air pressure 1 7 bar 15 100 psi Feed air inlet 1 4 GAS F Maximum delivery 21 l min 5 5 gpm Material inlet 1 2 GAS M Material outlet 1 2 GAS M Max air consumption 120 l min 4 clm Weight 6 Kg Noise pressure level 75 dB A Parts of the pump in contact with the material In the standard model in Aluminium code 8000 the parts are made of Aluminium AISI 12 UNI 5076 PTFE Galvanized st...

Страница 25: ...ND NEW EQUIPMENT The LARIUS 2 pump has been tested at our plant with light mineral oil left inside of the pumping elementi ad protection Before sucking the product carry out a washing using a diluent The suction hose diameter must be proper to the viscosity of the fluid to be pumped The installation of a filer at the end of the suction hose is recommended WORKING Dip the suction hose into the tank...

Страница 26: ...duct outlet hose feed the pump at minimum pressure and check it the pump starts wihout the outlet hose Inlet product line clogged Check the hose and the possible suction filer Clean Membrane broken Replace the mambrane Pilot valve blocked Press the reset push buttons placed on the sider of the valve Accelerated working and non suction of the pump There is no product Add the product The pump sucks ...

Страница 27: ...I n t e n t i o n a l l y b l a n k p a g e ...

Страница 28: ...11 10 27 26 25 19 20 22 21 3 2 4 35 36 47 48 24 23 20 19 18 1 6 5 2 34 33 21 22 20 19 23 24 25 26 28 28 29 31 31 30 32 27 46 42 41 40 39 38 37 43 44 45 29 LARIUS 2 SPARE PARTS LIST IN ALLUMINIUM EN www larius com 28 LARIUS 2 TRANSFER ED 10 01 2022 Cod 150146 K ...

Страница 29: ... 2 19 8012 Membrane pressing washer 4 20 301013 O ring 4 21 8013 PTFE membrane 2 8187 PTFE membrane abrasive products 2 22 8014 Rubber membrane 2 Pos Code Description Q ty 23 8011 Washer 2 24 8007 Elastic ring 2 25 8005 O ring 2 26 8004 Seal ring seat 2 27 8006 Seal ring 2 28 8021 Pilot pad 2 29 8009 Elastic ring 2 30 8010 Elastic pin 1 31 8043 O ring 2 32 8008 Rod 1 33 8001 Pump body 1 34 8047 Sc...

Страница 30: ...29 31 43 42 48 47 45 4 3 2 11 41 14 16 15 32 43 42 7 47 45 12 13 46 45 40 39 38 37 36 26 25 24 23 22 18 10 21 20 10 9 8 3 2 4 1 6 5 2 33 34 35 17 19 28 larius 2 SPARE PARTS LIST IN STAINLESS STEEL EN www larius com 30 LARIUS 2 TRANSFER ED 10 01 2022 Cod 150146 L ...

Страница 31: ...8 8012 Membrane pressing washer 2 19 8084 Screw 4 20 8013 PTFE membrane 2 8187 Membrane PTFE abrasive products 2 21 8014 Rubber membrane 2 22 8011 Washer 2 Pos Code Description Q ty 23 8007 Elastic ring 2 24 8005 O ring 2 25 8004 Seal ring seat 2 26 8006 Seal ring 2 27 8021 Pilot pad 2 28 8009 Elastic ring 2 29 8010 Elastic pin 1 30 8043 O ring 2 31 8008 Rod 1 32 8001 Pump body 1 33 8047 Screw 12 ...

Страница 32: ...1 1 9 12 12 13 13 11 11 8 2 8 7 6 11 11 10 10 12 12 11 11 8 8 1 1 2 10 3 9 2 2 3 3 10 40334 40331 40331 1 40335 KIT larius 2 SPARE PARTS LIST IN ALLUMINIUM STAINLESS STEEL EN www larius com 32 LARIUS 2 TRANSFER ED 10 01 2022 Cod 150146 M ...

Страница 33: ...e KIT 40334 Seat ball Balls LARIUS 2 Pos Description Q ty 1 O ring 4 2 Upper ball Ø9 16 2 3 Upper ball seat 2 9 Lower ball seat 2 10 Lower ball Ø3 4 2 Code KIT 40335 Engine gaskets Pos Description Q ty 4 Anello OR 2 5 Pilot pad 2 6 Ring 2 7 O ring 2 Code KIT 40331 Membranes LARIUS 2 Pos Description Q ty 8 Washer 2 11 O ring 4 12 PTFE membrane 2 13 Rubber membrane 2 EN www larius com 33 LARIUS 2 TR...

Страница 34: ... service for use of transfer low pressure double diaphragm pumps series 2 and 4 in potentially explosion Hazardous environments due to presence of gas or vapour Environment temperature 10 C 50 C Max fluid temperature C 60 C Max air temperature C 30 C Low pressure double diaphragm transfer pumps series 2 and 4 MARKING ATEX CERTIFICATE TECHNICAL FEATURES II 2 G c IIB T4 Tamb 10 C 50 C Tmax fluido 60...

Страница 35: ...d originated by a safe area Before proceeding with the installation carefully read the use and service manual All the service operations must be carried out as stated in the manual The low pressure double diaphragm transfer pumps series 2 and 4 must not work empty of material All the operations installation and service must be carried out by qualified operators SAFETY INSTRUCTIOINS FOR INSTALLATIO...

Страница 36: ...ius org manuali LARIUS_2_T_UK pdf DE http www larius org manuali LARIUS_2_T_D pdf FR http www larius org manuali LARIUS_2_T_F pdf ES http www larius org manuali LARIUS_2_T_E pdf LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com ...

Отзывы: