background image

Owner's

Manual

Please read  
this manual 
before  
operating  
your inverter

Pure Sine Wave 

Power Inverter

SSW-350-12A  
SSW-600-12A  
SSW-1000-12A
SSW-1500-12A
SSW-2000-12A

Содержание SSW-350-12A

Страница 1: ...Owner s Manual Please read this manual before operating your inverter Pure Sine Wave Power Inverter SSW 350 12A SSW 600 12A SSW 1000 12A SSW 1500 12A SSW 2000 12A...

Страница 2: ...ctions 3 2 How Your Inverter Works 5 3 Installation Environments 6 4 Operating Tips 10 5 Protective Features of the Inverter 12 6 Special Features 13 7 Troubleshooting Guide 14 8 Fuse Replacement 16 9...

Страница 3: ...t to the Ground terminals 3 Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This includes 12 V DC cigarette plug connections and terminal connections...

Страница 4: ...higher voltage drop Similarly thicker and shorter wire has lower resistance and hence produces lower voltage drop Hence symptoms of low DC input voltage battery power can result from wires that are ei...

Страница 5: ...ge is a DC to DC conversion process that raises the low voltage DC at the inverter input to high voltage DC of approximately 150 VDC The second stage is the actual inverter stage that converts the hig...

Страница 6: ...r source must provide between 11 0 and 15 0 VDC and the required current This DC power source must be a well regulated DC power supply or alternator and deep cycle battery system typically found in ve...

Страница 7: ...heck to make sure you have not reversed the polarity Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter Damage due to reverse polarity is not covere...

Страница 8: ...crimped soldered at the bare ends of the wires for secure connections 2 Ensure that the inverter s power switch is turned off and that no flammable fumes are present 3 Identify the Positive and Negati...

Страница 9: ...as the ground car floor or other solid surface The power cord allows easy positioning of the inverter The inverter should only be used in locations that meet the following criteria DRY Do not allow w...

Страница 10: ...switch ON again SIZING CHART FOR TYPICAL LOADS THAT REQUIRE HIGH STARTING SURGE The manufacturers specifications of the appliances and devices indicate only the running power required The surge power...

Страница 11: ...be used 5 Divide the total Watt Hours of energy on the AC side by 10 to get the total Ampere Hour of energy on the 12 VDC side to support the operation of the appliances 6 The Ampere Hour AH capacity...

Страница 12: ...al occurs the protection circuit activates and shuts down the inverter which prevents electric shock to humans Turn OFF the inverter unplug the fault AC appliance and then turn ON is the only way to r...

Страница 13: ...ES 1000W NO YES YES YES YES 1500W NO YES YES YES YES 2000W NO YES YES YES YES 1 Standard USB charging port 5 VDC 500mA 2 Compatible with specific SAMLEX SSW series remote control only Connection with...

Страница 14: ...nd Green LEDs are not lit No audible alarm Inverter has shut down due to overload In Models SSW 350 and SSW 600 this shut down could also be due to ground fault on the load side These models have buil...

Страница 15: ...e voltage drop due to thinner wires or loose connections in the DC input circuit Recharge the battery Use thicker DC input wires and tighten all DC input circuit connections AC output is available Aud...

Страница 16: ...that this inverter is equipped with a DC side fuses that are located inside the inverter Normally these fuses will not blow unless a serious problem occurs Please DO NOT replace the fuses yourself We...

Страница 17: ...CTOR NO NO YES YES YES PROTECTIONS LOW INPUT VOLTAGE WARNING ALARM 11 0 VDC LOW INPUT VOLTAGE SHUTDOWN 10 5 VDC HIGH INPUT VOLTAGE SHUTDOWN 15 3 VDC OVERLOAD SHUTDOWN YES COOLING LOAD CONTROLLED FAN Y...

Страница 18: ...pt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of...

Страница 19: ...110 17 Fawcett Rd Coquitlam BC Canada V3K 6V2 T 604 525 3836 F 604 525 5221 1 800 561 5885 e mail samlex samlexamerica com website www samlexamerica com SSW_Series_Inverters_Manual_Dec2010_1 0 1...