background image

IMPORTANT SAFETY PRECAUTIONS

Hazardous conditions may result if the charger is not installed or operated correctly.
Please read the following instructions to prevent personal injury or damage to the
charger:

Battery Related

To reduce the risk of battery explosion, follow these instructions and those marked
on the battery
Never smoke or allow an open spark or flame in the vicinity of the battery or engine
Charge only Lead Acid type of batteries ( Flooded / Absorbed Glass Mat (AGM ) /
Gel Cell ). Do not charge other type of batteries like Nickel Cadmium ( NiCad ) ,
Nickel-Metal Hydride ( Ni-MH ) , Dry-Cell etc. Other types of batteries might burst
causing personal injury
Never charge a frozen battery
Working in the vicinity of Lead Acid batteries is dangerous. Batteries generate
explosive gases during normal operation. Take necessary safety precautions when
installing the charger near a battery or in a battery compartment (Follow safety
instructions given by the battery manufacturer)
Never place the charger directly above or below the battery being charged; gases or
fluids from the battery will corrode and damage the charger. Locate the charger as far
away from the battery as DC cables permit. Do not install in the same compartment
as batteries

Charger Related

Do not operate the charger in a closed-in area or restrict ventilation in any way.
Install in a well ventilated, cool, dry place.
The charger must not be operated in a damp or wet environment. When mounting in
a boat, make sure it is not subjected to bilge water splash
Do not block the ventilation openings / openings for the cooling fan. There should be
at least 6 inches clearance all around the unit
Installation and wiring must comply with the local and the national electrical codes.
It is recommended that installation and wiring may be done by a certified electrician
Wrong installation on a boat may lead to corrosion of the boat. It is recommended
that installation on the boat must be carried out by a boat electrician
Disconnect the AC input power to the charger before connecting / disconnecting the
batteries or other DC loads or when working on the charger
Disconnect the AC input power before changing setting of the Dip Switch
The chassis of the charger is connected to the earth ground pin of the power cord
plug. Ensure that the earth ground pin of AC receptacle feeding the charger is
connected to earth ground
Do not use an adapter. If a grounding type of receptacle is not available, do not use
this charger until the proper outlet is installed by a qualified electrician.
Do not operate the charger if the power cord is damaged

Page 2

Содержание SEC - 1215A

Страница 1: ...Owner s Manual Please read this manual before operating your charger Switch Mode Automatic Lead Acid Battery Charger Model SEC 1215A SEC 1230A SEC 2415A...

Страница 2: ...IMPORTANT SAFETY PRECAUTIONS 2 DESCRIPTION AND FEATURES 3 CHARGING STAGES 4 PROTECTIONS 5 INSTALLATION 6 CHARGER OPERATION 7 8 9 10 TROUBLESHOOTING 11 12 INTERNAL FUSE RATINGS 12 SPECIFICATIONS 13 WAR...

Страница 3: ...n the same compartment as batteries Charger Related Do not operate the charger in a closed in area or restrict ventilation in any way Install in a well ventilated cool dry place The charger must not b...

Страница 4: ...simultaneously without use of an external battery isolator Monitoring through ON status LED and Ammeter Temperature controlled cooling fan SEC 1230A SEC 2415A Protections against short circuit over c...

Страница 5: ...e threshold of battery gassing termed boost or absorption voltage the charger automatically switches over to Stage 2 Boost or Absorption Stage The value of this voltage depends upon the type of batter...

Страница 6: ...draw a higher current than these limits the output voltage of the unit will start to drop The unit will automatically recover when the overload condition is removed Reverse Battery Connection Cut Off...

Страница 7: ...EC 1230A 0 19 inches CAUTION For firm connection when using stranded cable crimp solder pin style terminal on the charger end of the DC cables used for connecting to the battery other DC loads Cables...

Страница 8: ...cord conductors is Line L Black Neutral N White and Earth ground Green Selecting the Type of Battery and Charging Stages The Float Voltage and Boost Voltage Also called Absorption or Overcharge Voltag...

Страница 9: ...he charger In case the AC power fails or if there is no output from the charger the isolating diodes will prevent charging discharging among the batteries connected to the banks CAUTION When a bank co...

Страница 10: ...rame or engine block which is away from battery Do not connect to carburetor fuel lines or sheet metal body parts 6 For a positive grounded vehicle connect the negative black DC cable from the charger...

Страница 11: ...ent drawn by the DC load is below the maximum current rating of the charger Switch on the charger and then the DC load In a DC UPS Un interruptible Power Supply the charger simultaneously powers the D...

Страница 12: ...e charger is also feeding other DC load s in parallel with the battery The Dip Switch is not selected for Battery with Load Change Dip Switch setting to Battery under Load see under Powering other DC...

Страница 13: ...s Ensure that the starting inrush current or the maximum operating current of the load is lower than the current limit value of the charger INTERNAL FUSE RATINGS Both the AC side and DC sides have fus...

Страница 14: ...82 Short Circuit Overload 3 120 VAC 60Hz 230 VAC 50 Hz 50 60 Hz 14 VDC or 14 4VDC or Disabled 13 5 VDC 30A 0 40o C 2 9kg 6 4 lbs 10 8 x 8 4 x 3 3 273 x 214 x 82 Short Circuit Overload Over temperatur...

Страница 15: ...s the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by...

Страница 16: ...110 17 Fawcett Rd Coquitlam B C Canada V3K 6V2 T 604 525 3836 F 604 525 5221 e mail samlex samlexamerica com website www samlexamerica com 4 4 4 4XJUDI BOVBM...

Страница 17: ...Samlex America Inc 110 17 Fawcett Road Coquitlam B C Canada V3K 6V2 e mail samlex samlexamerica com website www samlexamerica com SEC1215A 1230A 2415A 031004...

Отзывы: