background image

 

 

 

 

2-2. Electrical Performance 

 

Specification 

Model No. 

Item  

SA-600R-112 

SA-600R-124 

Continuous Output Power 

600W 

Maximum Output Power (3Min.) 

680W 

Surge Rating 

800W 

Input voltage 

12V 

24V 

Output Voltage 

100 / 110 / 120V     +/- 3% 

Frequency 

(Switch Selections) 

50 / 60Hz     +/-  0.05% 

Efficiency (full load) 

87.0% 

90.0% 

No Load Current Draw 

0.87A 

0.43A 

Output Waveform 

Pure Sine Wave  ( THD < 3% ) 

Output voltage Regulation 

100 / 110 / 120V RMS -10%/+4% 

Input Voltage Regulation 

10.5-15 VDC 

21.0-30 VDC 

Input Level Indicator 

Red / Orange / Green     LED 

Load Level Indicator 

Failure Indicator 

Red LED 

Protection 

Overload, Short Circuit, Reverse Polarity (Fuse),  

Over / Under Input Voltage, Over Temperature. 

Safety Certification 

UL458 

EMC 

FCC Class B 

Operating Temperature Range 

0 - 33 

 

Storage Temperature Range 

-30

 to 70

 

Cooling  

Loading controlled cooling fan 

Dimensions 

295(L) x 180(w) x 72(H) mm / 11.61(L) x 7.09(W) x 2.83(H) Inch 

Weight 

2.7 kg     /     5.4 Lbs. 

 

Note: The specifications are subject to change without notice.

 

 

Содержание SA-600R Series

Страница 1: ...1 SA 600R Series Pure Sine Wave Inverter User s Manual...

Страница 2: ...ations 2 2 2 Electrical Performance 3 2 3 Mechanical Drawings 4 3 Instructions 5 3 1 Front Panel Operation 5 6 3 2 Rear Panel Operation 7 8 3 3 Installation 9 3 4 Quick hook up and Testing 10 11 3 5 A...

Страница 3: ...1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts your skin or clothing you need to wash it out immediately with soap and water If acid enters into your eyes immediately flush...

Страница 4: ...lications 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc 2 1 2 Office equipment computers printers monitors facsimile machines and scanners...

Страница 5: ...Regulation 100 110 120V RMS 10 4 Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC Input Level Indicator Red Orange Green LED Load Level Indicator Failure Indicator Red LED Protection Overload Short Ci...

Страница 6: ...4 2 3 Mechanical Drawing...

Страница 7: ...before you install and operate this model 3 1 Front Panel Operation 3 1 1 Front view PURE SINE WAVE INVERTER 3 1 2 ON OFF switch Leave the switch in the down position OFF during installation 3 1 3 In...

Страница 8: ...0W 580W Red Blink Over 580W 3 1 5 Failure Display failure status OVP over voltage protection UVP under voltage protection OTP over temperature protection OLP over load protection 3 1 6 AC outlet Outle...

Страница 9: ...perate the inverter with Remote ON OFF switch ON OFF switch on the Front Panel should be off 3 2 1 2 Ensure the remote control contact is off 3 2 1 3 Use 14 20 AWG wire to connect the Rear Panel Termi...

Страница 10: ...4V battery or other 12V 24V power source represents positive and represents negative Reverse polarity connection will blow the internal fuse and may damage the inverter permanently 3 2 4 Use wire 8 AW...

Страница 11: ...tom of the unit are not obstructed 3 3 5 Dust free Do not install the Inverter in dusty environment The dust can be inhaled into the unit when the cooling fan is working 3 3 6 Close to batteries Avoid...

Страница 12: ...wer inverter The red terminal represents positive and black terminal represents negative Insert the cables into the terminals and clamp the nuts and the wires securely WARNING You may observe a spark...

Страница 13: ...inally the buzzer will send out another beep sound and the input Level LED indicators will turn to Green color and the inverter starts working successfully 3 4 6 Set the power switch to OFF position t...

Страница 14: ...es such as inverters and generators which have their neutral conductors tied to ground in the same way as the neutral conductors from the utility tied to ground at the AC breaker panel For models conf...

Страница 15: ...the battery cables to the DC input terminals on the Inverter The cables should be as short as possible less than 10 feet 3 meters ideally and large enough to handle the required current in accordance...

Страница 16: ...Samlex recommends the following cables for optimum inverter performance Model No Wire AWG Inline Fuse SA 600R 112 4 100A SA 600R 124 6 50A Also use only high quality copper wiring and keep cable leng...

Страница 17: ...he starting currents for all the loads at one time 3 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the powe...

Страница 18: ...the lower red zone and cables No output voltage Thermal shutdown Improve ventilation Over Temp indicator on make sure ventilation shafts of the inverter Load less than 600W are not obstructed Lower a...

Страница 19: ...s product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us...

Страница 20: ...rica Inc 110 17 Fawcett Road Coquitlam BC V3K 6V2 Canada Toll free phone 1 800 561 5885 Toll free fax 1 888 814 5210 General Inquiries samlex samlexamerica com WWW http www samlexamerica com SA 600R_M...

Отзывы: