46 | SAMLEX AMERICA INC.
Ground fault on the load side or, if Neutral and Ground are bonded on the load side.
When tripped, the Green LED indication on the receptacle will be switched OFF. Remove
the cause of tripping. Switch ON the inverter if OFF and then, press the "Reset Button"
on the GFCI to reset (GFCI will not reset if the inverter is OFF and there is no AC volatge
on the internal Line Side of the GFCI).
10.7 INTERNAL DC SIDE FUSES
The following DC side fuses have been provided for internal protection of the DC input
side. The fuses are 58V.
PST-1500-48: 5 pieces of 10A in parallel = 50A total
PST-600-48: 2 pieces of 10A in parallel = 20A total
NOTE: The fuses are soldered to the PCB. Hence, these can be removed and replaced by
de-soldering and then re-soldering.
10.8 REVERSE POLARITY AT THE DC INPUT TERMINALS
The Positive of the battery should be connected to the Positive DC input terminal of
the inverter and the Negative of the battery should be connected to the Negative DC
input terminal of the inverter. A reversal of polarity (the Positive of the battery wrongly
connected to the Negative DC input terminal of the inverter and the Negative of the
battery wrongly connected to the Positive DC input terminal of the inverter) will blow
the external / internal DC side fuses. If the DC side fuse is blown, the inverter will be
dead. The Green LED marked "POWER" (2 in Fig 6.1 for PST-1500-48 and 2 in Fig 6.2 for
PST-600-48) and the Green indication light on the GFCI will be switched OFF and there
will be no AC output.
i
INFO
Reverse polarity connection is likely to damage the DC input circuitry. The internal fuse(s)
should be replaced with the same size of fuse(s) used in the unit. If the unit does not work
after replacing the fuse(s), it has been permanently damaged and will require repair /
replacement (Please read Section 11 - “Troubleshooting Guide” for more details).
!
CAUTION!
Damage caused by reverse polarity is not covered by warranty! When making battery
connections on the input side, make sure that the polarity of battery connections is correct
(Connect the Positive of the battery to the Positive terminal of the unit and the Negative of
the battery to the Negative terminal of the unit). If the input is connected in reverse
polarity, DC fuse(s) inside the inverter / external fuse will blow and may also cause
permanent damage to the inverter.
SECTION 10 |