background image

DC-DC Converter Manual

   |   3

IDC-200 | 

USER ManUal

SpECIfICatIonS

MoDEl 

no.

InpUt VoltaGE 

RanGE (VDC)

MaX InpUt 

CURREnt (a)

oUtpUt 

VoltaGE (VDC)

oUtpUt 

CURREnt (a)

IDC-200A-12

9 - 18

<30

12.5

20

IDC-200B-12

20 - 35

<15

12.5

20

IDC-200C-12

30 - 60

<10

12.5

20

IDC-200D-12

60 - 120

<5

12.5

20

IDC-200A-24

9 - 18

<30

24.5

10

IDC-200B-24

20 - 35

<15

24.5

10

IDC-200C-24

30 - 60

<10

24.5

10

IDC-200D-24

60 - 120

<5

24.5

10

IDC-200B-48

20 - 35

<15

48.0

4

IDC-200C-48

30 - 60

<10

48.0

4

no loaD CURREnt DRaW

< 25 mA

InpUt to oUtpUt ISolatIon

Yes. > 400V RMS

oUtpUt RIpplE & noISE

< 50 mV RMS

pEaK EffICIEnCY

85%

CoolInG

By temperature controlled fan

opERatInG tEMpERatURE 

anD DE-RatInG

-20 to +30oC / -4oF to 86oF   

(De-rate linearly to zero at 70oC / 158oF)

HUMIDItY, non-ConDEnSInG

Max 95%

pRotECtIonS

Overload / short circuit on the output side; 

Over voltage on the output side; Over voltage / 

transients on the input side; Reverse polarity on 

the input side; Over heating

SafEtY anD EMC StanDaRDS

eMissiONs 

EN55014-1

iMMuNiTy 

EN55014-2

AuTOMOTiVe DireCTiVe 

UN Regulation ECE R10-4

InpUt / oUtpUt ConnECtIonS 

Quick Connect ; Male, 6.3 mm /  

1/4" flat blade

DIMEnSIonS (W x D x H) 

88.0 x 175.4 x 50 mm / 3.5 x 6.9 x 1.9 in

WEIGHt 

0.6 Kg / 1.4 lb 

    NOTe: specifications are subject to change without notice

 

taBlE 1.  

exTerNAL iNPuT siDe Fuse & WiriNg 

MoDEl 

naME 

fUSE SpECS

WIRE SIZE (Up to 6 ft from Battery) 

(SEE notE 1 BEloW)

IDC-200A-12, 24

32V, 30A

AWG#8

IDC-200B-12, 24, 48

58V, 15A

AWG#14

IDC-200C-12, 24, 48

80V, 10A

AWG#19

IDC-200D-12, 24

125V, 5A

AWG#24

taBlE 2.  

exTerNAL OuTPuT siDe Fuse & WiriNg 

MoDEl 

naME 

fUSE SpECS

WIRE SIZE (Up to 6 ft from Battery) 

(SEE notE 1 BEloW)

IDC-200A-12

32V, 20A

AWG#10

IDC-200B-12

32V, 20A

AWG#10

IDC-200C-12

32V, 20A

AWG#10

IDC-200D-12

32V, 20A

AWG#10

IDC-200A-24

32V, 10A

AWG#16

IDC-200B-24

32V, 10A

AWG#16

IDC-200C-24

32V, 10A

AWG#16

IDC-200D-24

32V, 10A

AWG#16

IDC-200B-48

58V, 4A

AWG#22

IDC-200C-48

58V, 4A

AWG#22

5

88

58

175.4
168.0

• 

Height: 50 mm

• 

Use 4 mm bolt for mountin

g

NOTE: All measurements are in mm

  

Not to scale

Fig 1. Dimensions (Bottom View)

DIMEnSIonS & laYoUt

Fig 2(a). Layout (Front View)

5

1

2

3

4

6

Fig 2(b). Layout (Back View)

6

7

lEGEnD [for figs. 2(a) and 2(b)]

1. Input + Terminal

2. Input – Terminal

3. Output – Terminal

4. Terminal

5. Chassis Ground

6. Ventilation slots

7. Cooling fan (Exhausts outwards)

•  Quick Connect Male Terminals
•  6.3 mm / 0.25" flat blade

notES foR taBlE 1 anD 2:

a)   Wire sizes shown are based on 90oC / 194oF wire temperature rating and 2% voltage 

drop over distance of up to 6' from battery or load for current = Amp rating of the fuse.

b)   For distances > 6', use thicker wires to limit voltage drop to <2% for current = 

Amp rating of the fuse.

tERMInatIon of ConnECtInG WIRES:

c)  Use 6.3mm / 1/4" "Quick Connect", Female mating terminal on the connecting 

wiring. This type of terminal is available for maximum wire size of AWG #10. 

When using wires thicker than AWG #10, you may terminate the wire as 

follows:

 

•   Use 6.3mm / 1/4" "Quick Connect" Female matting connector (AWG #10 size)

 

•   Use around 2" piece of AWG #10 wire and crimp the connector to one 

end Solder / splice the other end of AWG #10 wire to wire the thicker wire

Use of short length of 2" of smaller AWG #10 wire will not increase voltage 

drop appreciably.

Содержание IDC-200

Страница 1: ...temperature controlled fan Install the unit in a cool dry and well ventilated space Do not block fan vent openings on the sides Do not install the unit inside engine compartment Do not connect disconnect input and output connections when live voltages are present For more information on input output grounding e g installation on Positive Grounding System refer to www samlexamerica com under Suppor...

Страница 2: ...rent will rise beyond the rated value and external fuse will blow if short circuit condition persists for longer duration There is automatic reset if the short circuit condition is removed before the fuse blows Reverse Polarity Over Voltage on the Output Side In case of i overvoltage on the outside 18V for 12V 30V for 24V and 60V for 48V or ii reverse polarity on the output side internal Zener Dio...

Страница 3: ...LE 2 External Output Side Fuse Wiring Model Name Fuse Specs WIRE SIZE Up to 6 ft from Battery see Note 1 below IDC 200A 12 32V 20A AWG 10 IDC 200B 12 32V 20A AWG 10 IDC 200C 12 32V 20A AWG 10 IDC 200D 12 32V 20A AWG 10 IDC 200A 24 32V 10A AWG 16 IDC 200B 24 32V 10A AWG 16 IDC 200C 24 32V 10A AWG 16 IDC 200D 24 32V 10A AWG 16 IDC 200B 48 58V 4A AWG 22 IDC 200C 48 58V 4A AWG 22 5 88 58 175 4 168 0 H...

Страница 4: ...ies which extend beyond those described herein This warranty is expressly in lieu of any other expressed or implied warranties including any implied warranty of merchantability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives There shall be no responsibility...

Отзывы: