8 | SAMLEX AMERICA INC.
• Investigate the cause of the malfunction by referring to “Fault Messages and
Troubleshooting Guide” in Table 7.1 of Section 7 of the EVO-RC Owner's Manual.
i
INFO
The optional EVO-RC Remote Control provides the user with the ability to modify the EVO Inverter
Charger’s operating parameters. The default settings in EVO Inverter Charger are adequate for some
installations but may have to be modified for others. It is strongly recommended that the user review the
EVO Owner’s Manual before putting any load or charging batteries.
11. Your EVO inverter Charger is delivered with various default configurations
The values will depend on the model you have. Refer to Section 6.4 starting at Pages 111
for a listing of programmable parameters and factory default values. The EVO-RC Owner’s
Manual is dedicated to the use of the optional Remote Control EVO-RC and includes
programming, and user instructions of these parameter.
12. The following parameters are the basic parameters which may require
modification depending on your configuration:
• Date and time
• Charging Voltages (Absorption, Equalization, Float)
• Charging current
• Power Saving Function
!
CAUTION!
If you are not sure of what parameters you need to change or what values to change to, consult your
point of purchase or call Samlex Tech Support. You should also consult a Certified Electrician who is
familiar with Local and National Electrical Codes to ensure a safe and code compliant installation.
13. The first parameter you should change is the Date and Time
To set time and date (no password required):
• Press Enter
• Press UP/Down to screen
SELECT GROUP
CHARGE CURVE
SELECT GROUP
TIME SETTING
TIME SETTING
2000/01/01 00:00
Up Key x 5
ò
Enter Key
ò
and then press Enter.
• Screen
SELECT GROUP
CHARGE CURVE
SELECT GROUP
TIME SETTING
TIME SETTING
2000/01/01 00:00
Up Key x 5
ò
Enter Key
ò
will appear. Date and time syntax is YYYY/MM/DD HR:MM
• Cursor will blink on value to be changed.
• Press Up/Down to change value.
• Press Enter to move to next value.
• When Date and time is correct, press and hold Enter to write your settings.
You are done setting the time and date.
This Quick Start Guide provides basic steps required for planning the installing and operating EVO
TM
Series Inverter Charger. Based on the specific application, actual installation procedure will vary.
Plan your installation accordingly. Please read the entire EVO
TM
Owner’s Manual. Samlex Customer
Service and Application Engineers are available to assist you with installation, setup, and operating
instructions.
EVO
TM
INVERTER/CHARGER |
Quick Start Guide
Содержание Evolution Series
Страница 9: ...SAMLEX AMERICA INC 9 Notes...
Страница 10: ...10 SAMLEX AMERICA INC Notes...
Страница 11: ...SAMLEX AMERICA INC 11 Notes...