TROUBLESHOOTING -GENERAL 

PROBLEM : Power ON/OFF switch does not illuminate when turned on.

 

PROBABLE CAUSE 

SUGGESTED REMEDY

 

No power in the AC outle

Check there is power in the outlet. 

AC side fuse inside the power  

Replace the fuse inside the unit.

supply is blown 

See fuse ratings at page 8

 

PROBLEM : AC side fuse blows as soon as power is turned on.

 

PROBABLE CAUSE 

SUGGESTED REMEDY 

Unit is defectiv

Please contact your dealer 

PROBLEM : The output voltage is 0 V or very low

 

PROBABLE CAUSE 

SUGGESTED REMEDY 

Input voltage is very lo

Check that the input voltage is 

 

V  

The unit is in current limit condition  

Check the output terminals are not 

due to overload caused by large reactive  

shorted. Remove the load. If the output 

loading or by the output being  

voltage gets restored, the load is shorted 

short circuited  

or is offering large reactive impedance. 

Unit is shut down due to over  

Check that the fan has not failed or 

temp. (SEC-1225G/1235 /2412G)   

the vent openings are not blocked 

PROBLEM : Output voltage drops as soon as the load is switched on 

PROBABLE CAUSE 

SUGGESTED REMEDY 

The unit is going into curren

t  

Reduce the load current to less than 

limit protection mod

e  

the current limit value. Motors, 

 

pumps, compressors,zrelays, incan-

 

descent and halogen lamps and large 

 

capacitors in the input section of the 

 

DC devices draw very high inrush or 

 

starting currents of up to 10 times 

 

their normal operating currents. 

 

Ensure that these inrush/starting 

 

currents are below the current limit 

 

value of the power supply. 

 

4

Содержание SEC-1212G

Страница 1: ...SEC 1212G SEC 1225G SEC 1235 SEC 2412G Model No AC DC POWER SUPPLY OWNER S MANUAL Please read this manual before operating your power supply Switch Mode AC DC Power supply...

Страница 2: ...e Important safety instructions 1 Description and features 2 Connection and operation 2 Cooling and fan control 3 Battery charging and back up 3 Trouble shooting 4 Switching power supplies RF Noise 5...

Страница 3: ...pins on the plug are the same number size and shape as those of the original power supply plug block or obstruct vent openings on the side bottom of the unit 5 Keep the unit away from moisture and wa...

Страница 4: ...ion and immunity standards CONNECTION AND OPERATION NOTE The DC output connector has a tubular hole of diameter 0 2 5mm with a set screw F of your 12V DC or 24V DCdevice Ensure that the power supply s...

Страница 5: ...N SUCTION ON THE BOTTOM AND THE DISCHARGE OPENINGS ON THE SIDES BATTERY CHARGING AND BATTERY BACK UP WARNING THESE UNITS ARE POWER SUPPLIES AND NOT BATTERY CHARGERS DO NOT CONNECT THESE UNITS DIRECTLY...

Страница 6: ...caused by large reactive shorted Remove the load If the output loading or by the output being voltage gets restored the load is shorted short circuited or is offering large reactive impedance Unit is...

Страница 7: ...noise and lose output voltage regulation due to excessive transmitter energy being coupled through the AC DC lines to the power supply s regulator feedback path This may be due to antenna being too cl...

Страница 8: ...bsorption of the ferrite coated cable avoids resonance s at high frequencies reducing the conducted and radiated RF noises even further b Use additional appropriate DC radio frequency interference RFI...

Страница 9: ...7...

Страница 10: ...e Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyo...

Страница 11: ...f April 20 2016 on the approximation of the laws of the Member States relating to electromagnetic compatibility and EC Low Voltage Directive For the evaluation regarding the electromagnetic interferen...

Страница 12: ...ic compability regulations 2016 For the evaluation regarding the electromagnetic interference the following EMC standards were applied EMI Class B EMS EN55022 2010 EN55024 2010 EN61000 3 2 2006 A2 200...

Страница 13: ...www samlex com www samlex solar com...

Отзывы: