![Sames CRN 457 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/sames/crn-457/crn-457_user-manual_804641025.webp)
Index revision : H
25
6336
Fault 3 is caused by excessive temperature inside the control module. In case of the control module
should reach a too high temperature, risking damaging it, the high voltage is switched off and a warning
message is displayed on the control module.
Work can be continued by pressing once on to the trigger to acknowledge the fault, but this latter will
come back every minute as long as the temperature has decreased to an acceptable level. An alarm will
remain displayed on the screen as long as the temperature is too high.
The operator will have to make the temperature decrease (Make sure as well that the temperature of the
compressed air is lower to 40°C).
Le Fault 4 appears when the trigger is engaged on start-up of the spray gun. The spray gun is rearmed
by releasing the trigger and pressing it again.
Fault 9 appears when there is a short-circuit on the gun. The spray gun is rearmed by releasing the
trigger and pressing it again. If the fault reappears systematically, check the wiring of the gun.
Faults 10 to 18 are detected when electrical power-supply faults occur on the different
solenoid valves; if a fault of this nature occurs: contact Sames Technologies.