Index revision : A
31
7140
All errors, except E220V, refer to the axis number which is shown on the left side of the Inomotion
display during operation. An error code, e.g. E1000, that has been observed during axis opera-
tion on page 2 does not mean that there is an E1000 error in all axes. It means that the module
sets an E1000 error for the axis.
The main page must be changed to the pages of the other active axes to observe the status
of each axis.
Error code
Symptoms
Remedies
E1
Start position error
- Check sensor connections and
whether it is defective
- Check if the belt is broken or too
loose
E2
Short stroke error
- Check the stroke parameters from
the programs via the interface. The
distance between the upper and
lower stroke limits is too short in rela-
tion to the set speed. Increase the
upper or lower stroke/reduce the
speed/increase the acceleration.
E4
Speed control communication error
-Check the communication cable
connection between the RS485
communication port and the reci-
procator electronic board.
-Check the accuracy of parameters
such as communication protocol,
address, communication speed
E8
Motor Overheating Error
- Visually inspect the motor. Check
for dust or powder on the motor.
- Check the cooling fan for opera-
tion or damage
E16
Coder error
- Check the coder connections
- The coder is connected to the
motor shaft by 2 set screws. Check
whether these screws are loose or
not.
- If it is loose, tighten it securely.
- If you still get an error, replace the
coder.
E1000
Axis communication error
- Check the communication cable
connections and if there are any
damaged cables.
- Check the connections of the reci-
procator's electronic board and if it
is faulty
E220V
Remote Trigger Error
The 230 VAC must be connected to
the trigger pin (Axis active / passive)
- The power switch on the control
cabinet (if present) must be in the
"On" position in order to supply the
Inomotion's
interlock connection
with 230 VAC.