Samcon RoughCam IPM3016 Скачать руководство пользователя страница 23

 
 
 

 
 

Doc.-ID: 181210-PT10BA-ES-RoughCam IPM3016_en_rev.00.docx, page 23 of 24 

 

Figure 10.1 

– Dimensions of the T10 RoughCam IPM3016 

 

 

 

 

Содержание RoughCam IPM3016

Страница 1: ...RoughCam IPM3016 User Manual...

Страница 2: ...Electrical connection 9 4 2 1 Potential equalization 10 4 2 2 Connection and protection 11 4 2 3 Connector pin assignment RJ45 12 4 2 4 Connection work on the terminal box 13 4 2 5 Tests prior to swit...

Страница 3: ...tion for model key LL N 15 Figure 4 8 Connection to the terminal box models with heating 16 Figure 5 1 Opening the RoughCam IPM3016 17 Figure 5 2 Location of the control button 18 Figure 5 3 Disconnec...

Страница 4: ...ange4 Cable length m 5 Cable termin 6 Lens7 RoughCam IPM3016 T10 VA1 2 K1 BOR N N 005 N P 090 046 017 T10 VA1 2 K1 BOR N N 005 N T 090 046 017 T10 VA1 2 K1 BOR LL N 005 N T 090 046 017 Table 2 1 Model...

Страница 5: ...6mm F2 0 46 34 T10 VA 1 2 K1 BOR X X XXX X X 017 tele Megapixel lens 16mm F1 8 17 12 2 2 Electrical parameters Power supply camera PoE IEEE 802 3af 802 3at Type 1 class 1 typical 2 9 W max 3 8 W LL mo...

Страница 6: ...TV module such as light sensitivity resolution frame rate sensor shutter times lens details streaming functions supported network protocols event trigger storage options and picture parameter setting...

Страница 7: ...cable glands made of brass nickel plated MsNi Sight glass material Borosilicate glass Ilmadur 10 I 420 Internal materials Optical and electronical components div ther moplastic plastics polyamide PA6...

Страница 8: ...afety guidelines given below in this user manual Attention Only original parts of SAMCON Prozessleittechnik GmbH may be used for repairs Repairs only be carried out in accordance with the nationally a...

Страница 9: ...ting options and additional accessories at http samcon eu Attention Prior to the camera installation take external sources of heat or cold into account Observe the permissible temperature range 4 2 St...

Страница 10: ...rging and hence spark generation The screw terminal on the housing s rear side is intended for this purpose q v figure 4 1 The profile of the potential equalization has to reflect the national groundi...

Страница 11: ...available for the RoughCam IPM3016 Possible cable terminations are terminal block plug or the hybride execution for the optional heating attention IEEE PoE specification then does not apply anymore F...

Страница 12: ...at the connecting side e g a PoE Switch a PoE Injector or Midspan which meets the specification IEEE 802 3af or 802 3at type 1 class 12 The interface of the RoughCam IPM3016 uses a 100 Mbit s Fast Et...

Страница 13: ...pply and protocol transfer is executed on separate pins plug pin contact 4 5 is the positive pole and 7 8 is the negative pole The T10 RoughCam Series supports both modes and the used power source PSE...

Страница 14: ...1 0 23 0 61 1 Tx PoE 48 VDC Tx OG 2 023 0 61 2 Rx PoE GND Rx WH GN 3 0 23 0 61 3 Rx PoE GND Rx GN 6 0 23 0 61 4 n a PoE 48 VDC WH BU 5 0 23 0 61 5 n a PoE 48 VDC BU 4 0 23 0 61 6 n a PoE GND WH BN 7...

Страница 15: ...D Rx GN 6 0 23 0 61 4 n c n c n c n c 5 n c n c n c n c 6 n c n c n c n c 7 n c n c n c n c 8 Shield A GND twisted pair GND Plug FOIL PE PE L 24 VDC n a WH BN BN 2 x 0 23 2 x 0 61 9 L Heater L GND n a...

Страница 16: ...r to commissioning all tests as indicated by the national regula tions have to be executed In addition it is mandatory that the proper functioning of the operating device in accordance with this user...

Страница 17: ...hardware reset it is allowed to open the housing All required steps are described in chapters 5 1 to 5 3 of this user manual 5 1 Work preparation Attention Please carry out any preoperational work car...

Страница 18: ...on the Axis modules main board q v Figure 5 2 the outer push button is used for carrying out the hardware reset Figure 5 2 Location of the control button In order to be able to press the control butt...

Страница 19: ...s run a risk of distorting the optical axis which leads to a reduction in the picture quality When touching electrical components potential equalization ground ing of the body has to be observed ESD c...

Страница 20: ...IP address The RoughCam IPM3016 is an Ethernet network camera requiring an IP address to ac cess it Usually a DHCP server is integrated in most networks which automatically as signs an IP address In c...

Страница 21: ...pany has to determine these intervals depending on the applica tion parameters During maintenance focus has to be put on checking the integrity of the housing the sealings and the cable glands If main...

Страница 22: ...hnical drawings of the T10 RoughCam IPM3016 For our RoughCam Series we have the same configuration options as for our ExCam Se ries Further drawings also for additional accessories 3D models STEP file...

Страница 23: ...Doc ID 181210 PT10BA ES RoughCam IPM3016_en_rev 00 docx page 23 of 24 Figure 10 1 Dimensions of the T10 RoughCam IPM3016...

Страница 24: ...Schillerstra e 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Отзывы: