Samcon ExCam XF Q1645 Скачать руководство пользователя страница 26

 
 
 

 
 

Doc.-ID: 190409-PT08BA-ES-ExCam XF-Q1645_en_rev.01, Page 26 of 32 

6.4 

Hardware Reset 

 
To set all the parameters of the ExCam XF Q1645 (including the IP address) to default 
values, you should run a hardware reset. 
The parameters can be reset via the web interface or manually. If  the camera placed in 
the network can no longer be reached or its state is uncontrollable,  the reset  should be 
performed manually. To do so, proceed as follows: 
 

1.  Disconnect the camera installation module (Axis Q1645) from the power supply. 
2.  Press  and  hold  the  control  button  (see  the  illustration  below)  and,  at  the  same 

time, connect the system to the voltage supply (PoE). 

3.  Hold the control button pressed for about 30 seconds. 
4.  Release  the  control  button.  After  about  a  minute,  the  AXIS  Q1645  will  return  to 

factory  defaults.  If  there  is  a  DHCP  server  in  the  network,  the  IP  address  will  be 
the following: 192.168.0.90 (subnet masking 255.255.255.0). 

5.  IP address and password can be redefined. If the hardware reset is not satisfacto-

ry or the network camera shows serious conflicts or does not work as usual (errors 
in  the  browser  visualisation,  frozen  images,  control  commands  no  longer  pro-
cessed,  slowing  down  of  the  system,  etc.),  it  may  be  necessary  to  re-install  the 
current firmware, or to install an update (see Chapter 7). 

 
 

6.5 

Closing of the pressure-resistant housing 

 
For closing the housing, proceed in reverse order as when opening. Use exclusively orig-
inal screws included in the supply.  
The  cable  and  power-supply  flange  (K3)  is  fixed  by  8  cylinder-head  screws  M4*0,0.7 
(ISO metric right-turning) with 30 mm thread length (DIN 912/ ISO 4762, grade 6g). Mate-
rials of bolted connections are identical to the pressure-resistant stainless steel housing 
(standard material no. 1.4404 AISI316L). Check whether the threaded holes are undam-
aged and clean. Before closing, it is also absolutely imperative to check the flame-proof 
gap (circular cylindrical fit).  
 

Attention! 
If any mechanical damages  occurred to the fitting gap, it is no longer 
allowed to use the housing! 

 
 

 

Attention! 

 

 

Do not lock-in any foreign objects in the housing. 

 

Dismantled screw locks (spring washers DIN 127A) must be used again. 
The GYLON® gasket must be used in undamaged condition, according to the flange hole 
pattern,  and placed between the flange and the hull.  The lateral position of the flat sur-
face / contact surface is arbitrary. 

Содержание ExCam XF Q1645

Страница 1: ...ExCam XF Q1645 User Manual...

Страница 2: ...a 15 5 3 2 Routing via ExConnection Rail optional accessories 16 5 3 3 Appropriate cables cable entries 17 5 3 4 Cable kits plug and play connection packages 18 5 3 5 Fusing 20 5 3 6 Plug assignments...

Страница 3: ...able cable kits 19 Table 5 4 Recommendation for fusing 20 Figure 5 10 Plug assignment RJ45 21 Figure 6 1 Removing the weather protection roof 1 2 this illustration is an example 23 Figure 6 2 Removing...

Страница 4: ...e visit our website at www samcon eu en When designing the ExCam XF Q1645 we attached a very high importance to safety mechanical precision and high quality of stainless steel 2 Technical data 2 1 Exp...

Страница 5: ...consumption 4 5 W 2 3 Connection cable Ex d Ex e ASKDP03 T Description Data transfer and power supply of the camera module compliant with DIN EN 60079 14 Jacket colour Green GN similar to RAL3001 Outs...

Страница 6: ...om products axis q1645 2 5 Other technical data Table 2 1 Other technical data Camera Ex d Terminal box Ex e Permissible ambient temperature 0 C 60 C for PoE power supply 60 C 60 C In the event of add...

Страница 7: ...mer is not allowed to make any alterations of the camera The camera must be operated in a proper and sound condition and only in the way intended Attention Repairs may only be carried out by using ori...

Страница 8: ...To ensure the best image quality delivered by the network camera plan the installation site carefully consider light conditions object distance or size angle and minimum object distance to the focus...

Страница 9: ...oducts network excam xf q1645 Optional mounting accessories Wall bracket WMB WALL MOUNT EXCAM XF 01569 001 Wall bracket for devices of T08 VA2 3 series Suitable for hanging the camera on walls Materia...

Страница 10: ...uipped with an electrical connection cable of the type ASKDP03 T The maximum transmission range from the camera to the next active network interface is 100 meters and can be individually specified by...

Страница 11: ...26 V DC Power consumption Approx 40W 60 C depends on temperature Power supply for the camera PoE Voltage supply PoE IEEE 802 3af 802 3at type 1 class 3 Reference voltage 48 V DC 44 54 V DC Maximum pow...

Страница 12: ...ES ExCam XF Q1645_en_rev 01 Page 12 of 32 Figure 5 2 Camera Ex d and terminal box Ex e Video Tutorial Observe our video tutorial SAMCON 01 Wiring the cable SKDP03 T to the junction box ExTB 3 https go...

Страница 13: ...Comment Reinforcement YE GN PE 2 5 mm 2 Flex Tx WH OG 1 0 32 mm 2 Solid conductor Tx OG 2 0 32 mm 2 Solid conductor Rx WH GN 3 0 32 mm 2 Solid conductor Rx GN 4 0 32 mm 2 Solid conductor PoE 48 VDC WH...

Страница 14: ...Doc ID 190409 PT08BA ES ExCam XF Q1645_en_rev 01 Page 14 of 32 Figure 5 4 Sample circuit of terminal box ExTB 3 Figure 5 5 Photo of the wired terminal box ExTB 3...

Страница 15: ...on Use only terminals approved by SAMCON Attention Finally check your network installation with a Class D Link Test 5 3 External connection and protection There are several options of routing the ExTB...

Страница 16: ...igure 5 7 ExTB 3 ExConnection Rail In the case of routing the ExTB 3 into an ExConnection Rail larger installation distances can be managed Note In hazardous areas the ExConnection Rail optional acces...

Страница 17: ...ble pro tection must comply with national and international regulations For non binding configuration and planning guidelines please visit our website Particularly for installations requiring a suitab...

Страница 18: ...The connection packages include everything you need for a professional system installation Figure 5 9 Cable kit plug play connection package a b c d 10 25 95 m ASKDP03 T sys tem cable digital a 1 bar...

Страница 19: ...et includes 25 meters SKDP03 T system cable digital 1 barrier gland Ex d 5 ml Loctite 243 screw locking One CAT6 RJ45 industrial plug 1 set of documents ASKDP03 T CABLE EXCAM 25M 01545 001 This cable...

Страница 20: ...L 4000 mA T slow blow high inrush load L 2 BU 1 5mm 2 stranded wire 0 V DC GND PE YE GN 1 5mm 2 stranded wire PE Table 5 4 Recommendation for fusing 5 3 6 Plug assignments RJ45 The data transfer of th...

Страница 21: ...g assignment RJ45 5 3 7 Tests prior to switching on voltage Attention Prior to starting the device perform all tests as indicated by the na tional regulations Furthermore check the correct function an...

Страница 22: ...ially explosive atmosphere 6 2 Opening the pressure resistant housing WARNING MAY NOT BE OPENED IN HAZARD AREAS Note Depending on classification of hazard areas it is imperative to obtain a work appro...

Страница 23: ...gon screws DIN 912 ISO 4762 together with their spring rings DIN 127A on the rear side of the cable and power supply flange see Figure 6 3 Cau tion do not touch the screw threads with your skin or clo...

Страница 24: ...k are fixed on the cable and supply flange Dealing with these components too you have to work very carefully and precisely in order to avoid canting and damage to the in built components Caution do no...

Страница 25: ...an also be accessed via FTP server in the network If the memory card has to be replaced by the user it should be as far as possible empty and pre formatted with an ext4 or vFAT file system When touchi...

Страница 26: ...rors in the browser visualisation frozen images control commands no longer pro cessed slowing down of the system etc it may be necessary to re install the current firmware or to install an update see...

Страница 27: ...mponents must always be tightened crosswise to a torque of 3 Nm Do not tighten the screw too strongly It can cause rupture of the cylinder head or over stretching the threads and thus to impairment of...

Страница 28: ...t the following website https www axis com products axis q1645 The delivered ExCam XF Q1645 is set to the applicable net frequency 50Hz or 60Hz If the camera is used at a location with a differing net...

Страница 29: ...is not possible to assign the IP address it might be necessary to change the firewall settings The AXIS IP Utility tool automatically recognizes all ExCam devices and visualises them in the device lis...

Страница 30: ...intenance measures are necessary they have to be initiated and or executed Repairs may only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resistant housings hav...

Страница 31: ...area of the product page on our website https www samcon eu en products network excam xf q1645 If you wish additional technical information please contact us at support samcon eu 11 Certificates and f...

Страница 32: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31...

Отзывы: