Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 34 of 40
For the execution with a „K2“ cable gland, 7 x cylinder head screws M4 x 0.7 (ISO metric
right-hand thread) with a thread length of 30 mm are used.
Please check that the bore holes and flameproof joint (cylindrical fit) are clean and intact.
Attention!
In case the flameproof joint has been damaged mechanically, the
housing must not be used anymore!
Attention!
Do not lock-in any foreign objects inside the housing
Please make sure that the disassembled screw locks (washer spring DIN 127A) are re-
assembled.
The GYLON® flat sealing must be intact and has to be reassembled according to the
hole-pattern of the flange. There is no restriction regarding the installation direction of the
sealing.
If, when closing the housing, it is noted that the surface of the flameproof joint is dirty or
not lubricated sufficiently, please clean it with a clean cloth and suitable cleaning deter-
gent. Afterwards, re-lubricate it with a suitable lubrication agent (e.g. Molykote® P-40
paste for standard applications or special lubrication agents such as OKS 403 for sea-
water environments
The screw connection of the flange and housing have to be tightened in crosswise se-
quence with a torque of
3 Nm
Please avoid extensive tightening
– this might lead to a
torn screw etc. affecting improperly the enclosure’s pressure resistance (Ex).
For the fixed installation of the ExCam IPM1145-(L), either with a wall mount bracket,
with a hinge attachment for sight-glass installations or for the optional installation of a
roof, please observe the instructions of the EX installation manual! Additional accessories
are available upon request.
The T08 ExCam series is certified to also be used for mobile applications (hand-held
etc.)!
The cylinder head screws for the safe connection of the housing body
and the flange have to be tightened with a torque of 3 Nm! Tighten the
screws in a crosswise sequence.