Doc.-ID: 150903-PT08BA-TG-ExCam IPM1145-(L)_en_rev.02.docx, page 18 of 40
gases including hydrogen, acetylene, carbon disulfide, flammable fibrous
material and non-conductive dusts)
5)
005
=
Length of the connection line in meter at delivery. The standard cable
length is 5 m (minimum/maximum cable length: 001
…100 [m])
Information: According to DIN EN 60079-14:2014 [chapter 10.6.2]) it is, at
a cable length of
≥
3 m, possible to use cable glands without an integrat-
ed pressure barrier as well as an elastomer sealing on the outer sheath
and an additional strain relief. At a cable length of < 3, the cable gland has
to be carried out with an integrated pressure barrier, this means with
epoxide compound grouting of the single conductors and with duroplast /
elastomer sealing on the outer sheath, dimensioned appropriately! The di-
mension of the cable glands are hence variable.
6)
K
=
Terminal block termination (
standard
)
SKD02-T:
CAT6a, 8x single conductor AWG22/1
„twisted pair“ solid
conductor copper blank, 0.33 mm
2
/ Ø=0.64 mm, approx. 6
mm striped, 1x shield CU-braid tinned 1.5 mm
2
with ferules
blue
Ölflex 440P:
Supply, 3G1.5mm
2
, Cu Sheath about 12 cm stripped and
furnished with bend relief / shrink tubing
P
=
Plug- termination (
optiona
l)
SKD02-T:
CAT6a, RJ-45 network plug (heavy duty), AWG 26-22,
e.g.: Type Weidmüller
„IE-PS-RJ45-FH-BK“ or type
Phoenix
Contact „VS-08-RJ45-5-Q/IP20“, contact assign-
ment always acc. to specification EIA/TIA-568B 1
Ölflex 440P:
Q.v. terminal block termination
Plug-termination
n/a
or upon request
(7)
N
=
Normal ambient temperature range (MTBF):
T
AMB_N
: 0 to +40 [°C]
L
=
Low ambient temperature range (MTBF):
T
AMB_L
: -30 to +40 [°C]
LL
=
Lowest ambient temperature range (MTBF):
T
AMB_LL
: -60 to +40 [°C]
H =
High ambient temperature range (MTBF):
T
AMB_H
: 0 to +70 [°C]
LH
=
Broad ambient temperature range (MTBF):
T
AMB_LH
: -30 to 70 [°C]
Note:
The upper temperature limits of type H and type LH of the functional temperature range (MTBF)
depend on the maximum power consumption of the applicable model options and are limited by the
explosion proof temperature range. Currently, model options ExCam IPM1145 and the ExCam
IPM1145-L are available. For the ExCam IPM1145-L, the upper temperature limit is reduced to:
T
AMB
…+65°C (T5).