SAM4S SPS-300 Series Electronic Cash Register AU
Service Mode Programming
•
147
PC Update - Program Area
1.
Connect the Serial Cable From ECR to PC.
2.
At the register, turn the control lock to the
S
position.
3.
Turn the power switch to the
OFF
position.
4.
Press and hold the
CASH
and
CLERK
keys. (Use the keys in their default locations, the
upper-right and lower-right keys on the keyboard.)
5.
While continuing to hold the
CASH
and
CLERK
keys, turn the power switch to the
ON
position. (The display will illuminate and the error tone will sound beep-beep-beep in
quick succession.) Release the keys.
6.
At the PC, execute the program
“NEWNET_DOWN.exe”. The Download dialog
box displays.
7.
Select the appropriate com port connection at your
PC at the PORT# option buttons.
8.
Click
SEL
. find the folder where the update files
are located and select S3xxXXXX.bin.
9.
Select
Program code
in the Select One option
buttons.
10.
Press
OK
Button. The download takes about 3½
minutes; the scroll bar will track the progress of the
download. At the ECR, the display will flash
slowly while the update is taking place.
11.
When complete, the message Completed displays on the PC. Click
OK
and the
Download program will close. At the ECR, a rapid beep-beep-beep will be heard, and the
display will flash rapidly, which indicates the update is complete.
12.
Turn the power switch to
OFF
on the register, the
Program Area
update is complete.
13.
Disconnect the PC cable.
14.
Perform a memory all clear on the ECR. The ECR is now ready to program or to load a
previously saved end-user program.