SAM4S SPS-300 Series Electronic Cash Register AU
Service Mode Programming
•
145
Application Area Update
1.
Set the control lock to the
S
position.
2.
Press and hold the Numeral
2
key on the keyboard. While continuing to hold the Numeral
2
key, turn on the power switch.
3.
Release the Numeral
2
Key.
4.
The display will flash between blue and red backlight, after a few seconds, the display
will continue to flash, but at a slower rate. This continues for about 1-minute while the
new program is being loaded. When the load is complete, a rapid beep-beep-beep will be
heard, and the display will flash rapidly.
5.
Power the register OFF. The Flash ROM update is complete.
6.
Remove the SD card from the register.
7.
Perform a memory all clear on the ECR. The ECR is now ready to program or to load a
previously saved end-user program.
Flash ROM update via PC by Flash Utility
Update Files
To complete the firmware update, you will be supplied with the following files:
•
NEWNET_DOWN.exe (The update utility program)
•
S3xxXXXX.bin (”XXXX” is the version number)
PC Connection Cable
YOU MUST USE Port #1
. Use the following cable:
•
CAB-E101PC9 (Register DB-9F COM 1 to PC DB-9F)