8 Troubleshooting
8-6
SAM4S NR-500 SERIES
Drawer Problem
Drawer Open
Failure ?
Y
N
1. Check the Drawer Connector & Harness.
2. Check the VDRW(Drawer Voltage).
3. Check the related circuit & Component TR TIP102(Q3)
4. Check the Harness and Solenoid in the Drawer.
5. Check the Drawer Signal (CPU P8.7)
Compulsory
Failure?
1. Check the Compulsory Harness & Connector.
2. Check the Micro switch in the Drawer.
N
Y
End