![Sam IQDMX3048-2A Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/sam/iqdmx3048-2a/iqdmx3048-2a_user-instruction-manual_3676412028.webp)
IQDMX30/IQDMX31
Controlling the IQDMX30/31 from the RollCall Control Panel
Issue 2 Rev 5
Page 28
© 2015 SAM
6.8.4 Audio Monitor
The Audio Monitor settings allow you to specify the level at which the audio signal is
considered to have dropped to silence and the level at which the audio signal is considered to
have risen to an overload condition.
•
Silent Level:
Use the slider bar to specify the level at which the signal is considered
to have dropped to silence. The range of this control is 0 to -80 dB in steps of 1 dB
and the preset value is -70 dB. The level set by this control must exist continuously for
the time specified by the Warning Timer control for the signal to be considered silent.
•
Overload Level:
Use the slider bar to specify the level at which the signal is
considered to have risen to an overload condition. The range of this control is 0 to
-80 dB in steps of 1 dB and the preset value is 0 dB. The level set by this control must
exist continuously for the time specified by the Warning Timer control for the signal to
be considered overloaded.
•
Warning Timer:
Use the slider bar to specify the time that either of the above
conditions must exist before considered to be true. The range of this control is 1 to
600 seconds in steps of 1 second. The preset value is 10 seconds