9.5
Installing built-in models
● Built-in models may
not be installed in com
bustible
worktops and appliance housings.
● Built-in models can be installed in CNS or
stone worktops up to 40 mm thick.
● It must be ensured that live electrical parts can
no longer be touched after installation.
● Do not install appliances on top of heat
sources.
Installation
Control panels and appliance top are preassem
bled. Do
not
pull off the connecting cables!
.
Make the installation cut-outs and mounting
holes as per drawing (page 32 chapter 9.6)
into the worktop and front panel.
.
Mount the corner posts.
.
Degrease bonding spots on the top of the ap
pliance and on the worktop.
.
Affix Si-foam sealing profile along the cut-out
‒ Si-foam sealing profile 5x3 mm self-adhe
sive, item no.: 604151.
● The sealing profile prevents the Pactan adhe
sive from being pressed in too far and the ad
hesive seal from becoming too wide.
.
Apply Pactan adhesive along the Si-foam seal
ing profile.
‒ Pactan adhesive set 7076 - 150 ml (TB 77)
with spatula, item no.: 888585
‒ Pactan cartridge 7076 - 310 ml, item
no.: 373060
.
Guide the front panel from the top through the
cut-out in the worktop and then out through the
front panel cut-out.
.
Insert the built-in module in the worktop cut-
out, align, press down and fasten with holding
rail.
.
Remove excess Pactan from the visible side.
.
Hook front panel on the top in the corner posts,
make contact below and screw tight.
Appliance with drain tap
.
Slide rosette on drain pipe.
.
To seal the drain tap's thread, apply Loctite
510 on the drain pipe.
.
Screw the drain tap on the drain pipe.
.
Fix the rosette and drain tap with screw on the
drain pipe.
Corner posts
Cut-out in front panel
on the furniture for
the control panel
Apply Pactan adhesive
all around with
approx. ø 8-10 mm
Si-foam sealing profile
Holding rail
Drain tap
Drain pipe
Rosette
Screw