2.2 Initial operation
The beverage cooling counter should be cleaned before starting the operation –
please see chapter 5 „cleaning and maintenance“.
Put in accessories like tray slides, wire shelves etc. according to the required
height in. Please make sure before connection that electrical current and voltage
are in accordance with the specifications on the nameplate. You will find the
nameplate on the left side in the installation compartment.
Initial operation / electrical connection refrigerated counters
series KTM / KSM / KKM:
See hereto picture 3 on page 22. Electrical connection has to be done over a
correctly installed sealed contact socket. We recommend connection to a
separate circuit (fuse 10A).
Initial operation / electrical connection refrigerated counters
series KTO / KSO / KKO:
See hereto picture 4 on page 22. Electrical connection has to be done over a
correctly installed sealed contact socket. We recommend connection to a
separate circuit (fuse 10A). All other connections like condensate drain,
refrigeration lines and control leads (on solenoid valve provided by the customer)
have to be done by local refrigeration/electric specialist.