page 10 / 12
11.
Possible errors and first steps for rectification
11.1 Cover does not close during vacuuming
Check whether
- the seal is correctly installed (see chapter 5).
- the contact point between cover and container is clean.
- the seal is worn or damaged. If yes, it must be replaced.
- the GreenVAC container is damaged (dents, etc.).
11.2 Maximum vacuum not reached
- Defective seals
- Deformed containers (dents, etc.)
- Product is too warm: Allow to cool.
- Vacuum unit is defective: Call your supplier.
11.3 Strong steam fittings on the lid
- The core temperature is too high, the product is too warm: allow to cool.
11.4 Suction of liquids
- The filling level has been exceeded (see chapter 7.1).
- The core temperature is too high, allow to cool.
- If no improvement is achieved, please contact your specialist retailer.