Electrical

MAKE ALL INSTALLATIONS IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES.

ELECTRICAL

The pump motor and solenoid are factory pre-wired.

Only one electrical connection is required if the control is 

installed with the provided wiring and mount. Run power 

from the building source to the 1/2” knockout on the bottom 

of the control.

If necessary, the control can be mounted remotely. 

Additional field wiring and hardware will be necessary. 

Contact service for installation advice.

IMPORTANT:

The pump must be checked for proper rotation as indicated 

by an arrow on the pump.

Complete wiring diagrams will be found inside control 

panel. Always use watertight conduit and fittings when 

wiring this product.

(Scrap Collector shown - Pot/Pan Scrap Collector similar)

 PHASE 

115V 

208V  230V  460-480V

  1 PH 

11 

5.5 

5.5 

  3 PH 

– 

3.2 

1.5

TOTAL FULL LOAD AMPS

PUMP MOTOR 3/4 HP

(Scrap Collector shown - Pot/Pan Collector similar)

COLD WATER

CONNECTION

HOT WATER

CONNECTION

AIR

GAP

WATER BLENDER

Plumbing

IMPORTANT:

The Salvajor Scrap Collector or Pot/Pan Collector is

equipped with a UPC approved air gap, eliminating the need 

for vacuum breakers.

DRAIN PIPING

Plumb a 2” pipe from the 2” male threaded nipple located 

on the bottom of the Collector reservoir tank to the nearest 

approved drain. The drain line should have a minimum of 

1/4” slope of fall per running foot. It is the responsibility of 

the plumbing contractor to check all connections to ensure 

they are free of leaks and meet all codes.

WATER SUPPLY

Plumb 3/4” lines from both hot and cold water supply 

sources and reduce to 1/2” before attaching to 

corresponding valves on the Scrap Collector or Pot/Pan 

Collector water harness. 

Note: Collector will not operate properly if water 

connections are reversed. Ball valves and water 

blender are clearly marked with hot and cold labels.

To assure against leaks, tighten water harness fittings. 

They may come loose during shipment, fabrication or 

installation. Pressure regulators should be installed in 

areas where water pressure exceeds the recommended 

maximum of 80 psi.

MAKE ALL PLUMBING CONNECTIONS IN ACCORDANCE

WITH NATIONAL AND LOCAL PLUMBING CODES.

2” NPT DRAIN

Содержание S914

Страница 1: ...ATIONAL PLUMBING AND ELECTRICAL CODES Scrap Collector Model S914 Pot Pan Scrap Collector Model P914 Installation Operating I N S T R U C T I O N S FOR PRODUCT WARRANTY REGISTRATION Go to www salvajor com Click on SUPPORT at the top of home page Click on PRODUCT REGISTRATION The Salvajor Company 4530 East 75th Terrace Kansas City Missouri 64132 2081 USA 1 888 SALVAJOR FAX 1 800 832 9373 www salvajo...

Страница 2: ... Top Box May ship separate Installation Operating Manual Collector Hardware Hose Clamps Gusher Plate and Gasket Flexible Recirculation Hose Collector Hardware X 12 X 12 X 4 Flexible Recirculation Hose Gusher Plate Gasket Hose Clamp Hose Clamp X 12 X 12 X 4 ...

Страница 3: ... table STOP If you have any questions about this installation call 1 888 SALVAJOR for installation advice X 12 X 12 X 4 Collector Top Collector Tank COLLECTOR HARDWARE GUSHER PLATE GASKET HOSE CLAMP FLEXIBLE RECIRCULATION HOSE ADJUSTABLE LEGS FLEXIBLE RECIRCULATION HOSE PUMP CONTROL HOSE CLAMP The control and sensor can be mounted on either side of the Collector with existing fasteners mounting ho...

Страница 4: ...ENDER Plumbing IMPORTANT The Salvajor Scrap Collector or Pot Pan Collector is equipped with a UPC approved air gap eliminating the need for vacuum breakers DRAIN PIPING Plumb a 2 pipe from the 2 male threaded nipple located on the bottom of the Collector reservoir tank to the nearest approved drain The drain line should have a minimum of 1 4 slope of fall per running foot It is the responsibility ...

Страница 5: ... button 2 times 2 Choose from 3 modes of operation Pressing ON OFF will cycle thru them On Off Mode Display reads SYSTEM ON Unit will run until turned off Water Saver Mode Display reads RUN TIME Unit will run at a normal flow rate until the operator leaves If the operator leaves the unit will run at a reduced flow rate until the operator returns or the run timer reaches 0 00 The unit will turn off...

Страница 6: ...oken Clamps loose Clogged pump Clogged pump intake screen Water plume valve turned down Pump motor running backwards Object blocking sensor Water Saver or Auto Start not turned on Dirty sensor Reset breaker Turn to ON position Replace blown fuse s Install overflow pipe Open valves Open valves Adjust setting of blender Correct water connections Wait for overload to reset and check for cause of rese...

Страница 7: ...unaltered has been properly installed maintained and operated Salvajor will repair or replace at no cost defective parts due to material or workmanship if such service is performed by a Salvajor Authorized Service Center Parts wear is not considered a defect Conditions not covered by this warranty Faulty or improper electrical installations faulty or improper plumbing installations disposer jammed...

Страница 8: ...bility to Buyer and or its customers exceed the price paid by Buyer for the specific goods provided by Seller giving rise to the claim or cause of action Buyer agrees that in no event shall seller s liability to buyer and or its customers ex tend to include incidental consequential or punitive damages The term consequential damages shall include without limitation loss of anticipated profits busin...

Отзывы: