MAKE ALL INSTALLATIONS IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES.
ELECTRICAL
The pump motor and solenoid are factory pre-wired.
Only one electrical connection is required if the control is
installed with the provided wiring and mount. Run power
from the building source to the 1/2” knockout on the bottom
of the control.
If necessary, the control can be mounted remotely.
Additional field wiring and hardware will be necessary.
Contact service for installation advice.
IMPORTANT:
The pump must be checked for proper rotation as indicated
by an arrow on the pump.
Complete wiring diagrams will be found inside control
panel. Always use watertight conduit and fittings when
wiring this product.
(Scrap Collector shown - Pot/Pan Scrap Collector similar)
PHASE
115V
208V 230V 460-480V
1 PH
11
5.5
5.5
–
3 PH
–
3.2
3
1.5
TOTAL FULL LOAD AMPS
PUMP MOTOR 3/4 HP
(Scrap Collector shown - Pot/Pan Collector similar)
COLD WATER
CONNECTION
HOT WATER
CONNECTION
AIR
GAP
WATER BLENDER
Plumbing
IMPORTANT:
The Salvajor Scrap Collector or Pot/Pan Collector is
equipped with a UPC approved air gap, eliminating the need
for vacuum breakers.
DRAIN PIPING
Plumb a 2” pipe from the 2” male threaded nipple located
on the bottom of the Collector reservoir tank to the nearest
approved drain. The drain line should have a minimum of
1/4” slope of fall per running foot. It is the responsibility of
the plumbing contractor to check all connections to ensure
they are free of leaks and meet all codes.
WATER SUPPLY
Plumb 3/4” lines from both hot and cold water supply
sources and reduce to 1/2” before attaching to
corresponding valves on the Scrap Collector or Pot/Pan
Collector water harness.
Note: Collector will not operate properly if water
connections are reversed. Ball valves and water
blender are clearly marked with hot and cold labels.
To assure against leaks, tighten water harness fittings.
They may come loose during shipment, fabrication or
installation. Pressure regulators should be installed in
areas where water pressure exceeds the recommended
maximum of 80 psi.
MAKE ALL PLUMBING CONNECTIONS IN ACCORDANCE
WITH NATIONAL AND LOCAL PLUMBING CODES.
2” NPT DRAIN