1 Product description 

The mini GlossTector 60° is one of the smallest gloss measurement gauges available 

on the market delivering precise results. It’s the product of choice for determining the 

gloss level of paints, coatings, plastics, ceramics and metal surfaces.  

 

2 Safety 

 If used properly there are no hazards to fear. 

 Don’t let children come in contact with the instrument to prevent it being damaged. 

 Do not perform any repairs on the units, neither mechanical nor electrical yourself. 

The unit must be opened by trained professionals only. Please contact our customer 

service department in such cases. They will be happy to assist you as quickly as 

possible. 

 Please take out the battery if you do not use the instrument for a longer period of 

time. 

 

3 General information 

  Before  using  the  mini 

Gloss

Tector 

60°  we  strongly  advice  you  to  read  the 

instructions’ manual. 

  After receiving a delivery, we ask you to check whether everything is included 

and not damaged.  

  The  instrument  consists  of  sensitive  optical  and  electronic  precision  part. 

Prevent it from being dropped. 

  Do not let any object to get into the aperture.  

  Do not expose the instrument to direct sunlight for a longer period of time. Do 

not store in a hot or dusty environment.  

  Avoid high levels of humidity and do not let the instrument get in contact with 

water or other fluids.  

  Protect the instrument from moisture, chemicals and corrosive vapors.  

  The calibration board and the housing are resistant to many solvents. However, 

we cannot guarantee resistance to all chemicals. You should therefore use a 

soft, moist cloth for cleaning. For cleaning excessive dirt and dust, use ethanol 

or cleaning alcohol. Do not use any acetone.  

Содержание Mini GlossTector 60

Страница 1: ...Mini GlossTector 60 Operations Manual ...

Страница 2: ......

Страница 3: ...4 2 SAFETY 4 3 GENERAL INFORMATION 4 4 POWER SUPPLY 5 5 OVERVIEW 6 6 GETTING STARTED 6 6 1 TURN ON 6 6 2 CALIBRATION 6 6 3 TESTING 7 6 4 TURN OFF 7 7 STATISTICS 7 9 DATA TRANSFER 8 10 ERROR NOTIFICATIONS 8 11 TECHNICAL DATA 8 12 STANDARDS 9 ...

Страница 4: ...d of time 3 General information Before using the mini GlossTector 60 we strongly advice you to read the instructions manual After receiving a delivery we ask you to check whether everything is included and not damaged The instrument consists of sensitive optical and electronic precision part Prevent it from being dropped Do not let any object to get into the aperture Do not expose the instrument t...

Страница 5: ...ply The instrument gets supplied with one 1 5V AAA LR03 alkaline battery Normally one battery should last for about 10000 measurements When the battery voltage approaches the required minimum level a notification will appear on the display Changing Battery Open the battery cover on the back of the instrument Insert a new battery into the battery box paying attention to the positive and negative po...

Страница 6: ...n mode The display shows CAL When the main button gets pressed the instrument calibrates to 97 0 Gu Its advisable to calibrate the instrument every time it gets turned on or after a long series of measurements to ensure optimal precision Note that on the gauge and on the holder one can see an arrow When placing the gauge in the holder make sure both arrows stand in line to each other 1 Calibration...

Страница 7: ... main button is pressed for 2 seconds 7 Statistics To enter the statistics mode press and hold the main button for about 2 seconds while its not placed in the holder The instrument will display N0 In statistics mode is possible to take up to 10 samples and the instrument will show the average and standard deviation of those data points Simply place the instrument at the points one wants to measure...

Страница 8: ...eu downloads 10 Error notifications Calibration error Clean the calibration standard and the lens carefully using ethanol or cleaning alcohol If the calibration should still not work contact Salutron Messtechnik GmbH our technical assistance is happy to help Wrong results If the gauge should display wrong results calibrate it and try again If the results should still be wrong contact Salutron Mess...

Страница 9: ...20 degrees 60 degrees and 85 degrees ASTM D 523 Standard test method for secular gloss DIN 67530 The reflect meter as an aid in evaluating gloss on level paint and plastic surfaces ISO7668 Anodized aluminum and aluminum alloys measurement of secular reflectance and secular gloss at angles of 20 60 and 85 ...

Страница 10: ......

Отзывы: