Salus TRV10RFM Скачать руководство пользователя страница 12

12

     TRV10RFM Instruction Manual

Using the Unit

Restoring Factory Default Settings

Press the pairing, open, and close buttons together for 10 seconds.

Protecting against Frost

When you have manually closed the valve, the unit automatically enables frost 

protection. Frost protection starts only when the temperature in the room drops 

below the frost temperature setpoint. The unit does all this automatically when 

connected to a thermostat and you don’t have to do anything.

Detecting Open Windows

The unit checks the rate of temperature drop in the room in which it is located. 

If the drop is rapid, it assumes a window in the room has been opened. This only 

works if the unit is paired to the thermostat and is in automatic mode and the 

battery in the unit is not low. The unit does all this automatically when connected 

to a thermostat and you don’t have to do anything. It works between 0 and 40⁰C.

Protecting against Lime Scale

Do not leave a valve open for a long time because this could cause a build up 

of lime scale. The unit has a lime-scale protection feature to prevent against 

this. The valve motor automatically starts once a week if no valve movement 

has been detected within a 14-day period. Lime-scale protection will continue 

to operate in automatic, manual open, and manual close modes and you don’t 

have to do anything.

Auto Adaptation

Once the batteries are inserted into the unit, the red light will appear. If no keys 

are pressed it will auto adapt to the valve.

Содержание TRV10RFM

Страница 1: ...Wireless Radiator Controller Model TRV10RFM INSTRUCTION MANUAL...

Страница 2: ...mportant info TRV10RFM 2 AA Batteries Adapter Manual Contents Box Contents Introduction Product Compliance and Safety Information Installation User Interface Status LED indication Installers notes War...

Страница 3: ...F wirelessboilerreceiverandotheriT600wirelessproducts Product Compliance ThisproductisCEcompliantandmeetsthefollowingECDirectives Electro MagneticCompatibility directive2004 108 EC R TTEdirective1999...

Страница 4: ...r off when requested by the thermostat See your boiler receivermanualformoreinformationabouttheRX1configuration Up to three units can be connected to a VS10RF VS20RF The unit is modulating which means...

Страница 5: ...ewiththeSALUSTRV Note If all the measurements are as stated on this page then the TRV will fit directly to your valve Also if your valve is not suitable please consider changingyourexistingvalves cont...

Страница 6: ...ckingthecompatibilityofyourheatingsystem 4 OurRA adapteralsofitsthisvalve OncefittedtheRAadaptershouldlooklikethis If you can not see any thread on the valve and it looks like this picture you may be...

Страница 7: ...iator valve using the mounting ringifneeded Screw the units nut finger tight to the radiator valve and check thattheLEDissolidred The unit is now ready for pairing to the SALUS thermostat Youmaynow st...

Страница 8: ...ur CO10RF Coordinator manualformoreinformation 2 Ensure the wireless thermostat is powered up and ready for pairing Seeyourthermostatmanualformoreinformation 3 If you are using the optional RX10RF wir...

Страница 9: ...pairuptothreeunitswith onethermostat Pairtheunitsroombyroom Readpage38to40ofyourwirelessthermostat manualwhentheredLEDontheunitstartsto flash You have paired the unit to the thermostat when the unit L...

Страница 10: ...ndication Leaving the Network Using the Unit Once paired to a thermostat press and hold the pairing button on the unit for 10 seconds The red and green status LEDs come on togetherforonesecond Note Af...

Страница 11: ...veManually Press the open button for 3 seconds The LED flashes green once and the valveopens ClosingtheValveManually Press the close button for 3 seconds The LED flashes red once and the valvecloses E...

Страница 12: ...located Ifthedropisrapid itassumesawindowintheroomhasbeenopened Thisonly works if the unit is paired to the thermostat and is in automatic mode and the batteryintheunitisnotlow Theunitdoesallthisautom...

Страница 13: ...work Pairwiththermostat Pairingbuttonfor10seconds Putunitinautomaticmode ShortpressPairingbutton Fullyopenthevalve Openbuttonfor3seconds Fullyclosethevalve Closebuttonfor3seconds Restorefactorydefault...

Страница 14: ...dication Automode Manualopen Manualclose Asequenceofredandgreen LEDsflashingdisplayed indicatesthesoftwareversion Redflashesthengoessteady Greenflashes orredflashes onfailuretoadapt Greensteady Greena...

Страница 15: ...aftershort pressonopenorclosebutton Redflashestwiceaftershort pressonopenorclosebutton Greenflashesonceaftershort pressonopenorclosebutton Redflashesonceaftershort pressonopenorclosebutton Greenflashe...

Страница 16: ...ally close LED flashes red once and then goes out To check status refer to previous page Short press to return to Auto mode Red LED will flash once to confirm that the unit is in AUTO Manual Override...

Страница 17: ...een Valve Adaptation Automatic Power Source 2x AA Batteries Battery Life 14 Months low battery indication Control Method Modulating Communication 2 4GHz ZigBee wireless Operating Temperature 0 to 45 C...

Страница 18: ...Notes 18 TRV10RFM Instruction Manual...

Страница 19: ...ecification for a period of five yearsfromthedateofinstallation SALUSControlssoleliabilityforbreachofthiswarranty willbe atitsoption torepairorreplacethedefectiveproduct Customer Name Customer Address...

Страница 20: ...ining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice SALUS Contr...

Отзывы: