Salus TRV10RFM Скачать руководство пользователя страница 2

Icons used in this manual:

 
 Safety

 

Important info

Contents:

Box Contents
Introduction
Product Compliance and 
Safety Information
Installation 
User Interface
Status/LED indication
Installers notes
Warranty

Innholdet i esken

Product Compliance & Safety Information

INTRODUCTION

The TRV10RFM is a battery-powered, mini-size thermostatic radiator valve (TRV) 

controller using ZigBee wireless communication. Simply replace the existing, 

passive head on the standard radiator valve with the TRV10RFM (referred to from 

now on as the unit). Use the unit with the VS10RF or VS20RF series of wireless 

thermostats and a Universal Gateway. 

VS10RF / VS20RF 

Thermostat

(Required)

UG600

(Required)

SALUS Wiring Centre

KL08RF

Checking the compatibility of your heating system

4

Our RA adapter also fits this valve.

Once fitted the RA adapter should look like this.

If you can not see any thread on 

the valve and it looks like this 

picture, you may be able  to use the 

RA adapter supplied.

TRV10 fits 30x1,5 mm thread.

Installing the Unit

Screw the units nut (finger 

tight) to the radiator valve 

and check that the LED is 

solid red.

Press any button on the 

unit to adapt it to the 

radiator valve. Once all 

adaptation noise and LED 

activity has stopped, the 

unit is ready to pair with 

your wireless thermostat. 

The unit is now ready 

for pairing to the SALUS 

thermostat. You may now 

start the pairing process.

4

5

6

Remove the battery door 

on the side of the unit.

Insert the batteries, 

ensuring correct

orientation.

1

2

3

The LED on the unit flashes 

green then flashes red before 

changing to solid red. When 

it is solid red, place the unit 

over the radiator valve using 

the mounting ring if needed:

Contents of the box

For the latest PFD Instruction Manual, go to

www.salus-controls.com

TRV10RFM

2 AA Batteries

Adapter

Manual

Box Contents

 

Product Compliance 

This product is CE compliant and meets the following EC Directives: Electro-Magnetic Compatibility 

directive 2014/30/EU; 2014/53/EU and 2011/65/EU.

                 

 

Safety   Information 

Use in accordance with the regulations. The unit is to be used  for the control of room temperature 

inside the house.

                

  

Installation 

This accessory must be fitted by a competent person, and installation must comply with the 

guidance, standards and regulations applicable to the country or state where the product is 

installed. Failure to comply with the relevant standards could lead to prosecution.

RX10RF

(Optional)

System Overview

To achieve the best control from the unit and thermostat, we recommend they are 

used with the SALUS system receiver configured to RX1. The system receiver will 

turn the boiler on or off when requested by the thermostat. See your boiler receiver 

manual for more information about the RX1 configuration.

+

Up to 6 units can be connected to a VS10RF/VS20RF

The unit is modulating, which means it opens or closes partially 

or 100% depending on the relationship between the actual room 

temperature and the required room temperature measured by 

the VS10/20RF.

Checking the compatibility of your heating system

The SALUS TRV10RFM is compatible with the majority of thermostatic radiator valves. 

Before fitting, please check your valve is suitable for use with the SALUS TRV.

Valve

Remove the TRV head

Note:

 If all the measurements are as stated on this page then  the TRV will fit directly 

to your valve. Also if your valve is not suitable please consider changing your existing 

valves, contact your installer.

Measure the thread diameter 

(must measure 30mm)

1

2

mm

10

20

30

3

mm

10

20

30

40

50

Measure the pin length of the valve 

when it is in the open position.

(must measure between 13-16mm)

Preparing to Pair the Unit

1

Press and hold the button on the Universal Gateway for 

five seconds. This puts the Universal Gateway in pairing 

mode. See your Universal Gateway manual for more 

information.

2

Ensure the wireless thermostat is powered up and 

ready for pairing. See your thermostat manual for more 

information.

3

If you are using the optional RX10RF wireless boiler receiver configured for 

remote boiler switching, ensure this has been powered up and the red LED 

has gone from flashing to steady. See your boiler receiver manual for more 

information.

Pairing the Unit

Press and hold the pairing button for 10 seconds. 

You can pair up to 6 units with one thermostat. 

Pair the units room by room.

You have paired the unit to the thermostat when the unit LED goes off.  

Once paired, the unit operates in automatic mode and receives room temperatures 

from the thermostat.

LED Indication

Pairing Button

Manual  open/

status indication

Manual close/

status  indication

Using the Unit

Leaving the Network

Once paired to a thermostat, press and hold the 

pairing button on the unit for 10 seconds.

The red LED come on together for one second.

Note:

 After you have deleted the unit from the 

wireless network, you must reinstall the TRV see 

Installing the unit.

Содержание TRV10RFM

Страница 1: ...Wireless Radiator Controller Model TRV10RFM INSTRUCTION MANUAL ...

Страница 2: ...tion Product Compliance and Safety Information Installation User Interface Status LED indication Installers notes Warranty Innholdet i esken Contents of the box For the latest PFD Instruction Manual go to www salus controls com TRV10RFM 2 AA Batteries Adapter Manual Box Contents ...

Страница 3: ...ll turntheboileronoroffwhenrequestedbythethermostat Seeyourboilerreceiver manualformoreinformationabouttheRX1configuration Up to 6 units can be connected to a VS10RF VS20RF The unit is modulating which means it opens or closes partially or100 dependingontherelationshipbetweentheactualroom temperature and the required room temperature measured by the VS10 20RF ...

Страница 4: ...ourheatingsystem 4 OurRA adapteralsofitsthisvalve OncefittedtheRAadaptershouldlooklikethis If you can not see any thread on the valve and it looks like this picture youmaybeable tousethe RA adaptersupplied TRV10fits30x1 5mmthread ...

Страница 5: ...you are using the optional RX10RF wireless boiler receiver configured for remote boiler switching ensure this has been powered up and the red LED has gone from flashing to steady See your boiler receiver manual for more information Pairing the Unit Press and hold the pairing button for 10 seconds You can pair up to 6 units with one thermostat Pairtheunitsroombyroom You have paired the unit to the ...

Страница 6: ...at Required UG600 Required SALUS Wiring Centre KL08RF Product Compliance ThisproductisCEcompliantandmeetsthefollowingECDirectives Electro MagneticCompatibility directive2014 30 EU 2014 53 EUand2011 65 EU Safety Information Useinaccordancewiththeregulations Theunitistobeused forthecontrolofroomtemperature insidethehouse Installation This accessory must be fitted by a competent person and installati...

Страница 7: ...usewiththeSALUSTRV Valve RemovetheTRVhead Note Ifallthemeasurementsareasstatedonthispagethen theTRVwillfitdirectly toyourvalve Alsoifyourvalveisnotsuitablepleaseconsiderchangingyourexisting valves contactyourinstaller Measurethethreaddiameter mustmeasure30mm 1 2 mm 10 20 30 3 mm 10 20 30 40 50 Measurethepinlengthofthevalve whenitisintheopenposition mustmeasurebetween13 16mm ...

Страница 8: ...topped the unit is ready to pair with yourwirelessthermostat The unit is now ready for pairing to the SALUS thermostat You may now startthepairingprocess 4 5 6 Removethebatterydoor onthesideoftheunit Insertthebatteries ensuringcorrect orientation 1 2 3 The LED on the unit flashes green then flashes red before changing to solid red When it is solid red place the unit over the radiator valve using t...

Страница 9: ... indication Using the Unit Leaving the Network Once paired to a thermostat press and hold the pairingbuttonontheunitfor10seconds TheredLEDcomeontogetherforonesecond Note After you have deleted the unit from the wireless network you must reinstall the TRV see Installingtheunit ...

Страница 10: ... safe mode the unit opens the valve 25 for water flow to maintain room temperature Toenterfailsafemode pressandholdtheopenandclosebuttonstogetherfor3seconds Toexitfailsafemode pressthe Pairingbuttontoputtheunitinautomaticmode Openbuttonfor3secondstoopenthevalve Closebuttonfor3secondstoclosethevalve RestoringFactoryDefaultSettings Pressthepairing open andclosebuttonstogetherfor10seconds Protectinga...

Страница 11: ...automatically starts once a week if no valve movement has been detected within a 14 day period Lime scale protection will continue to operate in automatic manual open andmanualclosemodesandyoudon thavetodoanything AutoAdaptation Oncethebatteriesareinsertedintotheunit theredlightwillappear Ifnokeysarepressed itwillautoadapttothevalve Button Usage Todothis Pressthe Leavethenetwork Pairingbuttonfor10...

Страница 12: ... LED flashes red once and then goes out To check status refer to refer to table above Short press to return to Auto mode Red LED will flash once to confirm that the unit is in AUTO To remove the unit from auto mode follow the steps below If the buttons are locked unlock them by pressing the pairing and close buttons together for3seconds Manual Override ...

Страница 13: ...hes twice after short press on open or close button No LED Red and green on together for one second Green flashes for up to 10 minutes 25 open 100 open 0 open Wireless link to thermostat lost Normal operation Battery low Error installing Auto mode Manual open Manual close Auto mode Auto mode Manual open Manual close Window open mode active Green and red flash alternately after short press on open ...

Страница 14: ...urce 2x AA Batteries Battery Life 14 Months low battery indication Control Method Modulating Communication 2 4GHz ZigBee wireless Operating Temperature 0 to 45ºC Storage Temperature 20 to 60ºC Operating Humidity 5 to 95 RH Protection IP30 Size mm H 88 6 W 51 Manual open status indication Manual close status indication Pairing Input Three push buttons ...

Страница 15: ...its specification for a period of five years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option torepairorreplacethedefectiveproduct Warranty Customer Name Customer Address Post Code Tel No Email Engineers Company Tel No Email Instalation Date Engineers Name Engineers Signature ...

Страница 16: ...TECHNICAL T 44 0 1226 323961 E tech salus tech com Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice SALUS Controls is a member of the Computime Group Issue Date Dec 2014 00086 2 ForPDFInstructionManualgoto www salus controls com ...

Отзывы: