Salus TRV10RFM Скачать руководство пользователя страница 15

Press for 3 seconds

to manually open 

Press for 3 seconds

to manually close

LED flashes green once and then goes out.

To check status refer to table above.

LED flashes red once and then goes out. 

To check status refer to refer to table above.

Short press to return to Auto mode.

Red LED will flash once to confirm that

the unit is in AUTO.

Using the Unit 

Auto Lock Function

Auto lock function is disabled until you have gone through the pairing process. After 

pairing, the TRV will  auto lock after 5 minute if no buttons have been pressed.

Unlocking the Buttons

To unlock the buttons, press the pairing and close buttons together for 3 seconds. 

Opening the Valve Manually

Press the open button for 3 seconds. The LED flashes green once and the valve opens.

Closing the Valve Manually

Press the close button for 3 seconds. The LED flashes red once and the valve closes.

Entering Fail Safe Mode

In fail safe mode, the unit opens the valve 25% for water flow to maintain room 

temperature.
To enter fail safe mode, press and hold the open and close buttons together for 3 seconds.
To exit fail safe mode, press the:

•  Pairing button to put the unit in automatic mode

•  Open button for 3 seconds to open the valve

•  Close button for 3 seconds to close the valve

Restoring Factory Default Settings

Press the pairing, open, and close buttons together for 10 seconds.

Protecting against Frost

When you have manually closed the valve, the unit automatically enables frost 

protection. Frost protection starts only when the temperature in the room drops below 

the frost temperature setpoint. The unit does all this automatically when connected to a 

thermostat and you don’t have to do anything.

Using the Unit

Detecting Open Windows

The unit checks the rate of temperature drop in the room in which it is located. If the drop 

is rapid, it assumes a window in the room has been opened. This only works if the unit is 

paired to the thermostat and is in automatic mode and the battery in the unit is not low. 

The unit does all this automatically when connected to a thermostat and you don’t have 

to do anything. It works between 0 and 40⁰C.

Protecting against Lime Scale

Do not leave a valve open for a long time because this could cause a build up of lime scale. 

The unit has a lime-scale protection feature to prevent against this. The valve motor 

automatically starts once a week if no valve movement has been detected within a 14-

day period. Lime-scale protection will continue to operate in automatic, manual open, 

and manual close modes and you don’t have to do anything.

Auto Adaptation

Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed 

it will auto adapt to the valve.

Button Usage

To do this… 

Press the…

Leave the network 

Pairing button for 10 seconds (when unit already in network)

Pair with thermostat 

Pairing button for 10 seconds

Put unit in automatic mode 

Short press Pairing button

Fully open the valve 

Open button for 3 seconds

Fully close the valve 

Close button for 3 seconds

Restore factory default settings  Open, pairing, and close buttons together for 3 seconds
Lock and unlock the buttons 

Pairing and close buttons together for 3 seconds

Wireless Radiator Controller

Model: TRV10RFM

I N S T R U C T I O N  M A N U A L

www.salus-controls.com

SALUS Controls plc

SALUS House

Dodworth Business Park South,

Whinby Road,

Dodworth, Barnsley S75 3SP, UK.

SALES:

 

T: +44 (0) 1226 323961

 

E: [email protected]  

TECHNICAL: 

T: +44 (0) 1226 323961

 

E: [email protected]  

Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change 

specification, design and materials of products listed in this brochure without prior notice.

SALUS Controls is a member of the Computime Group

Issue Date: Dec  2014

00086/2

For PDF Instruction Manual go to 

www.salus-controls.com

Technical Detail

SALUS Controls warrants that this product will be free from any defect 

in materials or workmanship, and shall perform in accordance with its 

specification, for a period of five years from the date of installation. 

SALUS Controls sole liability for breach of this warranty will be (at its option) 

to repair or replace the defective product. 

Warranty

Model

 TRV10RFM

Type

 

Hydraulic Radiator Valve

 

DC Motor

 

M30 x 1.5

LED Indicator

 

Bi-Colour, Red/Green

Valve Adaptation

 Automatic

Power Source

 

2x  AA Batteries

Battery Life

 

14 Months (low battery indication)

Control Method

 Modulating

Communication

 

2.4GHz ZigBee wireless

Operating Temperature

  0 to 45ºC

Storage Temperature

 

-20 to 60ºC

Operating Humidity

 

5 to 95”RH

Protection

 IP30

Size (mm)

 

H 88.6, W 51

•  Manual open/status indication

•  Manual close/status indication

• Pairing

Customer Name: ..................................................................................
Customer Address: ..............................................................................
....................................................... Post Code: ....................................
Tel No: ................................................................................................. 
Email: ..................................................................................................

Engineers Company: ............................................................................
Tel No: .................................................................................................
Email: ..................................................................................................
Instalation Date: ..................................................................................
Engineers Name: .................................................................................
Engineers Signature: ...........................................................................

To remove the unit from auto mode, follow the steps below. If the buttons 

are locked, unlock them by pressing the pairing and close buttons together 

for 3 seconds.

Manual Override

LED Indications

 

100% open

 

0% open

 

1 to

 

100% open

 

0% open

 

100% open

 

0% open

 

100% open

 

25% open

Power switched 

on or after reset
Unit adapting

to valve

Unit has not 

joined network 

or has not paired 

to thermostat

Unit paired to 

thermostat and 

in auto mode
Leaving network
Identifying the 

network

When... 

The LEDs... 

Valve

Software Version 

indication

Auto mode

Manual open

Manual close

A sequence of red and green LEDs flashing 

displayed indicates the software version 
Red flashes then goes steady. Green flashes (or red 

flasheson failure to adapt). Green steady.

Green and red flash (or red flashes on failure to adapt)
Green and red flash alternately after short press on 

open or close button
Green flashes twice after short press on open or 

close button
Red flashes twice after short press on open or 

close button
No LED

Red and green on together for one second
Green flashes for up to 10 minutes

25% open

100% open

0% open

Wireless

link to 

thermostat

lost

Normal

operation

Battery low

Error installing

Auto mode

Manual open

Manual close

Auto mode

Auto mode

Manual open

Manual close

Window open 

mode active

Green and red flash alternately after short press on 

open or close button

Green flashes twice after short press on open or 

close button
Red flashes twice after short press on open or 

close button
Green flashes once after short press on open or 

close button
Red flashes once after short press on open or 

close button
Green flashes twice after short press on open or 

close button
Red flashes twice after short press on open or 

close button

Green and red flash twice every 10 seconds

Red flashes three times every 10 seconds

(less if the battery is low)
Green and red flash alternately

Input

 

Three push buttons:

Содержание TRV10RFM

Страница 1: ...Wireless Radiator Controller Model TRV10RFM INSTRUCTION MANUAL ...

Страница 2: ...tion Product Compliance and Safety Information Installation User Interface Status LED indication Installers notes Warranty Innholdet i esken Contents of the box For the latest PFD Instruction Manual go to www salus controls com TRV10RFM 2 AA Batteries Adapter Manual Box Contents ...

Страница 3: ...ll turntheboileronoroffwhenrequestedbythethermostat Seeyourboilerreceiver manualformoreinformationabouttheRX1configuration Up to 6 units can be connected to a VS10RF VS20RF The unit is modulating which means it opens or closes partially or100 dependingontherelationshipbetweentheactualroom temperature and the required room temperature measured by the VS10 20RF ...

Страница 4: ...ourheatingsystem 4 OurRA adapteralsofitsthisvalve OncefittedtheRAadaptershouldlooklikethis If you can not see any thread on the valve and it looks like this picture youmaybeable tousethe RA adaptersupplied TRV10fits30x1 5mmthread ...

Страница 5: ...you are using the optional RX10RF wireless boiler receiver configured for remote boiler switching ensure this has been powered up and the red LED has gone from flashing to steady See your boiler receiver manual for more information Pairing the Unit Press and hold the pairing button for 10 seconds You can pair up to 6 units with one thermostat Pairtheunitsroombyroom You have paired the unit to the ...

Страница 6: ...at Required UG600 Required SALUS Wiring Centre KL08RF Product Compliance ThisproductisCEcompliantandmeetsthefollowingECDirectives Electro MagneticCompatibility directive2014 30 EU 2014 53 EUand2011 65 EU Safety Information Useinaccordancewiththeregulations Theunitistobeused forthecontrolofroomtemperature insidethehouse Installation This accessory must be fitted by a competent person and installati...

Страница 7: ...usewiththeSALUSTRV Valve RemovetheTRVhead Note Ifallthemeasurementsareasstatedonthispagethen theTRVwillfitdirectly toyourvalve Alsoifyourvalveisnotsuitablepleaseconsiderchangingyourexisting valves contactyourinstaller Measurethethreaddiameter mustmeasure30mm 1 2 mm 10 20 30 3 mm 10 20 30 40 50 Measurethepinlengthofthevalve whenitisintheopenposition mustmeasurebetween13 16mm ...

Страница 8: ...topped the unit is ready to pair with yourwirelessthermostat The unit is now ready for pairing to the SALUS thermostat You may now startthepairingprocess 4 5 6 Removethebatterydoor onthesideoftheunit Insertthebatteries ensuringcorrect orientation 1 2 3 The LED on the unit flashes green then flashes red before changing to solid red When it is solid red place the unit over the radiator valve using t...

Страница 9: ... indication Using the Unit Leaving the Network Once paired to a thermostat press and hold the pairingbuttonontheunitfor10seconds TheredLEDcomeontogetherforonesecond Note After you have deleted the unit from the wireless network you must reinstall the TRV see Installingtheunit ...

Страница 10: ... safe mode the unit opens the valve 25 for water flow to maintain room temperature Toenterfailsafemode pressandholdtheopenandclosebuttonstogetherfor3seconds Toexitfailsafemode pressthe Pairingbuttontoputtheunitinautomaticmode Openbuttonfor3secondstoopenthevalve Closebuttonfor3secondstoclosethevalve RestoringFactoryDefaultSettings Pressthepairing open andclosebuttonstogetherfor10seconds Protectinga...

Страница 11: ...automatically starts once a week if no valve movement has been detected within a 14 day period Lime scale protection will continue to operate in automatic manual open andmanualclosemodesandyoudon thavetodoanything AutoAdaptation Oncethebatteriesareinsertedintotheunit theredlightwillappear Ifnokeysarepressed itwillautoadapttothevalve Button Usage Todothis Pressthe Leavethenetwork Pairingbuttonfor10...

Страница 12: ... LED flashes red once and then goes out To check status refer to refer to table above Short press to return to Auto mode Red LED will flash once to confirm that the unit is in AUTO To remove the unit from auto mode follow the steps below If the buttons are locked unlock them by pressing the pairing and close buttons together for3seconds Manual Override ...

Страница 13: ...hes twice after short press on open or close button No LED Red and green on together for one second Green flashes for up to 10 minutes 25 open 100 open 0 open Wireless link to thermostat lost Normal operation Battery low Error installing Auto mode Manual open Manual close Auto mode Auto mode Manual open Manual close Window open mode active Green and red flash alternately after short press on open ...

Страница 14: ...urce 2x AA Batteries Battery Life 14 Months low battery indication Control Method Modulating Communication 2 4GHz ZigBee wireless Operating Temperature 0 to 45ºC Storage Temperature 20 to 60ºC Operating Humidity 5 to 95 RH Protection IP30 Size mm H 88 6 W 51 Manual open status indication Manual close status indication Pairing Input Three push buttons ...

Страница 15: ...its specification for a period of five years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option torepairorreplacethedefectiveproduct Warranty Customer Name Customer Address Post Code Tel No Email Engineers Company Tel No Email Instalation Date Engineers Name Engineers Signature ...

Страница 16: ...TECHNICAL T 44 0 1226 323961 E tech salus tech com Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice SALUS Controls is a member of the Computime Group Issue Date Dec 2014 00086 2 ForPDFInstructionManualgoto www salus controls com ...