66
• If LED diode of the Network Status is flashing, pair the wiring centre with
the system in accordance to the manual instruction and pair thermostat
with wiring centre.
7.
CONNECTIVITY
LOST TRV
Thermostat lost contact with the TRV
head.
• Check TRV head batteries.
• Send the heating signal from thermostat and check if the TRV
head is working.
• If the LED diode on the TRV head is flashing, repeat the pairing
procedure with thermostat according to the manual instructions.
8.
CONNECTIVITY
LOST RX 1
Thermostat has lost connection with
the RX10RF receiver (RX1 mode).
• Is the RX10RF receiver plugged to the power supply and the top
LED diode is red? The Auto/Manual switch has to be set to AUTO
position.
• Force identification process from the coordinator/gateway side
and check if the devices are within the network.
• Send the heating signal from thermostat
• If the top LED diode is flashing, perform the pairing procedure
according to the RX10RF manual instruction.
9.
CONNECTIVITY
LOST RX 2
Thermostat has lost connection with
the RX10RF receiver (RX2 mode).
• Is the RX10RF receiver plugged to the power supply and the top
LED diode is red? The Auto/Manual switch has to be set to AUTO
position.
• Force identification process from the coordinator/gateway side
and check if the devices are within the network.
• Send the heating signal from thermostat
• If the top LED diode is flashing, perform the pairing procedure
according to the RX10RF manual instruction.
10-17.
CONNECTIVITY
LOST ZONE 1-8
Wiring centre has lost connection
with thermostat of the given zone:
e.g. 11 = with zone 1; 12 = with the
zone 2 etc. Error is displayed on all
thermostats.
• Check the thermostat power supply.
• Send the heating signal from thermostat.
• If necessary, reinstall the thermostat.
18.
WC / CB LOST
CONNECTIVITY
Wiring centre has lost connection
with the CO10RF coordinator/UGE600
internet gateway.
Error is displayed on all thermostats.
• Is the wiring centre turned ON and Status Network LED diode
solid?
• Force identification process from the coordinator/gateway side
and check if wiring centre is within the network.
• If LED diode of the Network Status is flashing, pair the wiring
centre with the system in accordance to the manual instruction and
pair all thermostats with wiring centre.
19.
WC / CB LOST
LINK-RX10RF
Wiring centre has lost connection
with the RX10RF receiver operating in
RX1 mode.
Error is displayed on all thermostats.
• Is the wiring centre turned on? Status Network LED diode should
be solid.
• Force identification process from the coordinator/gateway side
and check if devices are within the network.
• If the LED diode of the AUTO/MANUAL receiver switch is flashing,
follow the RX10RF manual instruction for pairing.
ERROR
CODE
DISPLAY
DESCRIPTION
ERROR DESCRIPTION
TROUBLESHOOTING