21
reservoir from boiler circuit
CH
(starting
P2
pump).
Night cooling- Yes
enables/
NO
disables night
cooling mode in hours 0
00
÷5
00
.
Night cooling ON
–
DHW reservoir temperature
(
T2
sensor), when exceeded at 0
00
if night
cooling function is enabled, the controller will
decide on night cooling activation.
Night
cooling
OFF
–
DHW
reservoir
temperature (
T2
sensor), to which the
controller will be cooling down the reservoir
(if night cooling function is enabled and if in
hours
0
00
÷5
00
Night
cooling
ON
temperature is exceeded).
Alarm TCOLcr
–
Switching on (YES) or off (NO)
the
alarm
on
exceeding
TCOLcr
temperature. This function will not affect the
controller operation. If the parameter is set
as NO, the controller will not alarm when
TCOLcr
temperature is exceeded at the
collector sensor.
13.9.
Solar thermal scheme H
Loading of DHW reservoir with two collector sets
oriented toward two directions.
Fig. 13.8 Solar thermal scheme H
The collector pump
P1
of collector
A
will
be started at 100% capacity, if the difference
between
T1
and
T2
exceeds the value of
dTonDHW
and it will be working for the time
specified in parameter
tP
. If after this time the
difference between
T1
and
T2
is still above
dTonDHW,
the pump speed will remain at
100%. If the said difference between
T1
and
T2
drops below
dTonDHW,
the controller will start
reducing the pump speed, until the difference
between
T1
and
T2
reaches the value specified
as
dToffDHW
. If the difference between
T1
and
T2
is between the values
dTonDHW
÷
dToffDHW
, the controller will calculate and set
the pump speed proportionally. When
dToffDHW
is reached, the pump will work at minimal speed
(
Pmin
), below it will be stopped.
The collector pump
P2
of collector
B
will
be started at 100% capacity, if the difference
between
T3
and
T2
exceeds the value of
dTonDHW
and it will be working for the time
specified in parameter
tP
. If after this time the
difference
T3
and
T2
is still above
dTonDHW,
the pump speed will remain at 100%. If the said
difference between
T3
and
T2
drops below
dTonDHW,
the controller will start reducing the
pump speed, until the difference between
T3
and
T2
reaches the value specified as
dToffDHW
. If
the difference between
T3
and
T2
is between the
values
dTonDHW
÷
dToffDHW
, the controller
will
calculate
and
set
the
pump
speed
proportionally. When
dToffDHW
is reached, the
pump will work at minimal speed (
Pmin
), below
it will be stopped.
The system will work, until
T2
sensor
reaches
TsDHW
preset, then collector pumps
P1
and
P2
are stopped.
If
T1 or T3
collector temperature reaches
critical value (
TCOLcr
), then the controller will
allow switching on pump
P1
or
P2
(depending
which collector has critical temperature) in order
to reduce the collector temperature below
hysteresis
HP1
for
P1
and
HP2
for
P2
.
If the reservoir temperature at
T2
sensor
reaches the value of
TDHWmax,
the controller,
despite
of
critical
collector
temperature
(
TCOLcr
), will stop the collector pumps,
disabling the collector cooling. It is to protect the
reservoir from overheating.
List of parameters in
Adjustment
menu
TsDHW-
Reservoir temperature preset
Night cooling- YES
enables/
NO
disables night
cooling mode in hours 0
00
÷5
00
.
Night cooling ON
–
DHW reservoir temperature
(
T2
sensor),
when
exceeded
at
0
00
if night cooling function is enabled, the
controller will decide on night cooling
activation.
Night
cooling
OFF
–
DHW
reservoir
temperature (
T2
sensor), to which the
controller will be cooling down the reservoir
(if night cooling function is enabled and if in
hours
0
00
÷5
00
Night
cooling
ON
temperature is exceeded).
Alarm TCOLcr
–
Switching on (YES) or off (NO)
the
alarm
on
exceeding
TCOLcr
temperature. This function will not affect the
controller operation. If the parameter is set
as NO the controller will not alarm after
TCOLcr
is exceeded for the collector sensors
T1
and
T3
.
13.10.
Solar thermal scheme I
Loading of pool system.
Fig. 13.9 Solar thermal scheme I
Содержание PCSol 201
Страница 1: ...INSTALLATION AND OPERATION MANUAL REVISION 1 1_EN Controller PCSol 201 FOR SOLAR COLLECTORS 07 2020 ...
Страница 2: ......
Страница 6: ......
Страница 7: ...OPERATING MANUAL PCSol 201 ...
Страница 27: ...INSTALLATION MANUAL PCSol 201 ...
Страница 54: ...54 ...
Страница 55: ......
Страница 56: ...SALUS Controls Made in Poland ...