Installation and wiring guide

www.salus-controls.com  Technical Helpline 00000 000000

When using option 2 refer to device 

parameters on page xx of the manual.

Thermostat Grouping

The thermostats can work as individual units or in groups. There can be up to 2 groups of

thermostats per wiring centre. In order to work in groups the communications cable must be

connected to the wiring centre communications terminals (+ & -). The (-) terminals are

common to all thermostats. In order to assign the thermostat to group 1 or 2 then the

communications cable + must be connected to the relevant 1 or 2 + terminal.

This must be carefully removed or
replaced when removing or replacing
the wiring centre cover, being careful
to ensure the correct orientation.

Dip Switch Set Up

In order for the wiring centre to be able to control UFH
and Radiators, there is a need to turn off the UFH pump for
a zone when that zone is to be used for radiators.

Eg. When fitting a zone for radiators or towel rail then the
Dip Switch for that zone should be switched to OFF.
The Dip Switches for this are located under the front lid.
When the zone switch is in the ON position the UFH pump
will run when that zone is calling for heat along with the
boiler. When it is in the OFF position then the UFH pump will
not run but the boiler will fire.

There are three other function switches as well. 

Pump & Boiler delay:

This gives a three minute delay to

allow actuators to open before the boiler fires.

Pump Only Delay:

Delays only the UFH pump from firing

for three minutes.

Actuator NC or NO:

This refers to Normally Open or

Normally Closed. This should be set to NC for JG products.

Motorised Valves, Pump, Boiler & Stat Connections

Ribbon Connection

Fuses

Status Neon’s

T

hermostat Z

ones

Groups

1
2

Actuator Connections

Actuator connections corresponding to the thermostat
connections. Up to 2 cables can be used in each
connection (4 Actuators per Zone) If more, that number
needs to be connected, then an external junction box
will be needed. A maximum of xxx actuators can be
connected to a zone in this manner.

7

If hot water is part of a group then
the communication connection
must be connected to group 1.

8

5

3

2

6

4

8

Optional Cylinder Thermostat: 

If connecting the cylinder thermostat

directly to the timer then a link needs to be fitted between IN and OUT.

Optional Hot Water Motorised Valve: 

Used if timed hot water is required.

Optional Overheat Thermostat:

Used for connecting a pipe thermostat to

prevent over temperature water damaging sensitive floors. Remove the link
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
open if overheating occurs and 
the UFH pump will stop running.

Optional Boiler Enable: 

This Volt Free connection must come from the boiler

thermostat connection, when any zone calls for heat the Boiler enable will
close causing the boiler to run. If work is being carried out on the boiler then
power to and from the switch will cease. (Do not connect to the boiler IN
terminal by linking a 230V feed from the wiring centre)

Optional UFH Motorised Valve: 

If a UFH motorised valve is 

fitted then remove the link between OR and GR.

Optional Heat/Cool Changeover: 

This connection allows heat/cool

changeover of all thermostats using a single external switch (installer supplied).

Switch: 

Open-Heating    Closed-Cooling

Option 1

Connect Cylinder

Thermostat to

wiring centre

Option 2

Connect Cylinder

Thermostat to RF

Thermostat for wire

free connection. A

link will be needed

between IN & OUT

as shown by arrow.

IN

HW CYLINDER 

THERMOSTAT

HW MOTORISED VALVE

OVERHEAT  STAT

UFH PUMP

BOILER ENABLE

UFH MOTORISED VALVE

OUT

IN OUT

IN OUT

BR EA N OR GR

BR EA N OR GR

L N E

ZONE 1

ZONE 2

ZONE 3

ZONE 4

SL N L

SL N L

SL N L

SL N L

SL N L

HW TIMER CONNECTION

THERMOSTAT CONNECTIONS 230V AC

230V AC

Hot Water Connections

IN

HW CYLINDER 

THERMOSTAT

HEET

COO

HW MOTORISED VALVE

OVERHEAT  STAT

UFH PUMP

BOILER ENABLE

UFH MOTORISED VALVE

OUT

IN

IN OUT

IN OUT

BR EA N OR GR

BR EA N OR GR

L N E

ZONE 1

ZONE 2

ZONE 3

ZONE 4

SL N L

SL N L

SL N L

SL N L

SL N L

SL

HW TIMER CONNECTION

THERMOSTAT CONNECTIONS 230V AC

230V AC

Sensor Terminals

Can be used for external AIR,
Floor sensor when configured
as thermostat. Can also be
used for cylinder thermostat
when connected for HW.

OPTONAL HOT
WATER
MOTORISED
VALVE

OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED

OPTONAL HOT
WATER
MOTORISED
VALVE

OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED

1

iT600 Wiring Centre KL10 005_Layout 1  05/06/2014  16:23  Page 2