5.2 Indicator Tests

Let’s take the indicator testing of S3871FB solid-state power amplifier as an example, which can be used
as a reference for other models of solid-state power amplifiers.

1. Testing Instruments and Equipment

Major instruments and equipment required as shown in the table below:

SN

Instrument

Main technical indicators

1

Vector network analyzer

Frequency range: 0.5GHz - 40GHz

2

Signal source

Frequency range: 0.5GHz - 40GHz

3

Power meter

Frequency range: 0.5GHz - 40GHz

4

Power sensor

Frequency range: 0.5GHz - 40GHz

5

Spectrum analyzer

Frequency range: 0.5GHz - 40GHz

6

Attenuator

Frequency range: 0.5GHz - 40GHz

Note: Other instruments that can meet the requirements for indicator testing can be used as substitutes.

2. Indicator Testing Methods
2.1 Normal functionality inspection

Connect the S3871FB solid-state power amplifier to the power supply, place the power switch on the rear
panel to the "-" position (the "On" position), and the standby power indicator on the front panel will be on.
When the working switch on the front panel is turned on, the fans on both sides of the rear panel of the
housing will rotate, the working indicator near the working switch on the front panel is on, the display on
the output power display screen is normal and the key sensitivity is OK.

2.2 Performance characteristics testing

The specific operation steps for testing the following indicators are provided according to the testing
instrument shown in the figure. When other testing instruments with the same performance characteristics
are used for testing, please refer to the User Manual of such instruments for the specific operation. A
signal source and a power meter as shown in Figure 5-2 can also be used to test the gain.

(1) Gain test

a) Testing equipment:
Vector network analyzer:

3672

1

High-power attenuator:

89-30-21

1

Calibration cable:

2

2.4mm calibration piece:

85056A 1 set

b) Testing diagram

Содержание S3871 Series

Страница 1: ...S3871 Series Solid State Power Amplifier User Manual Saluki Technology Inc...

Страница 2: ...54dB S3871AK Power Amplifier 80MHz 1GHz 56dB S3871AA Power Amplifier 1GHz 2 5GHz 53dB S3871AP Power Amplifier 1GHz 2 5GHz 55dB S3871AB Power Amplifier 1GHz 6GHz 48dB S3871AQ Power Amplifier 2GHz 6GHz...

Страница 3: ...r 37GHz 43GHz 46dB S3871FE Power Amplifier 26GHz 40GHz 43dB S3871FF Power Amplifier 26GHz 40GHz 49dB S3871FG Power Amplifier 26GHz 40GHz 53dB S3871FP Power Amplifier 18GHz 40GHz 46dB S3871FQ Power Amp...

Страница 4: ...C 150 6GHz 18GHz 150W S3871DH 005 2GHz 18GHz 5W S3871DH 010 2GHz 18GHz 10W S3871DK 080 2GHz 18GHz 80W S3871EB 040 18GHz 26 5GHz 40W S3871EB 060 18GHz 26 5GHz 60W S3871EB 080 18GHz 26 5GHz 80W S3871EC...

Страница 5: ...r tampered by any organization or individual or reproduced or transmitted for the purpose of making profit without its prior permission otherwise Saluki will reserve the right to investigate and affix...

Страница 6: ...886 909 602 109 Email sales salukitec com www salukitec com 6 Contacts Service Tel 886 909 602 109 Website www salukitec com Email sales salukitec com Address No 367 Fuxing N Road Taipei 105 Taiwan R...

Страница 7: ...peration Guide 11 3 1 Front Panel Features 12 3 2 Rear Panel Features 13 Chapter 4 Working Principle 14 Chapter 5 Technical Specifications and Indicator Tests 15 5 1 Main Indicators and Performance Ch...

Страница 8: ...atibility testing high power electric vacuum device testing non linear testing of high power components and so on As indispensable important instruments in broadband high power testing systems they ha...

Страница 9: ...hnical Indicators section of this manual And please pay special attention to the following requirements Power supply 220V 10 50Hz 5 Power socket 3 core power socket must be used and grounding is stric...

Страница 10: ...reduce electrostatic damage ensure correct grounding of all instruments prevent the generation of static electricity operators must wear anti static wrist straps before touching the connectors the cor...

Страница 11: ...s and gains In terms of protective design the instrument features many alarm and protection functions Firstly the instrument offers air cooling alarm and protection over temperature alarm and protecti...

Страница 12: ...RF input signals of the solid state power amplifier 3 RF Output connector The RF output connector is used for outputting the RF output signals of the solid state power amplifier 4 Gain Power Regulator...

Страница 13: ...working switch of the front panel is in the standby state by default and will be switched to the working state after pressing the key 3 2 Rear Panel Features The configuration of the rear panel of S3...

Страница 14: ...etting Wizard keys on the front panel of the instrument the working state can be set to Open Loop At this time microwave signals are input from the RF frequency input end of the amplifier then amplifi...

Страница 15: ...3871AH 80MHz 1GHz 54 51 N f N f S3871AK 80MHz 1GHz 56 53 N f N f S3871AA 1GHz 2 5GHz 53 50 N f N f S3871AP 1GHz 2 5GHz 55 52 N f N f S3871AB 1GHz 6GHz 48 45 N f N f S3871AQ 2GHz 6GHz 53 50 N f N f S38...

Страница 16: ...2 4mm m 2 4mm m S3871FF 26GHz 40GHz 49 46 2 4mm m WR28 S3871FG 26GHz 40GHz 53 50 2 4mm m WR28 S3871FP 18GHz 40GHz 46 43 2 4mm m 24JS18000 S3871FQ 18GHz 40GHz 50 47 2 4mm m 24JS18000 S3871FR 18GHz 40G...

Страница 17: ...tput power VS Frequency S3871EA Output power VS Frequency S3871DA Output power VS Frequency S3871AA Output power VS Frequency S3871AB Output power VS Frequency 2 General information 1 Environmental re...

Страница 18: ...state power amplifier to the power supply place the power switch on the rear panel to the position the On position and the standby power indicator on the front panel will be on When the working switc...

Страница 19: ...lid state power amplifier clockwise to the end conduct the gain test according to the connection system shown in Figure 5 1 and record the value S21 as the gain value of the amplifier 2 Input port vol...

Страница 20: ...the max output power degree and the attenuation value on the attenuator which is just the max output power 2 Max input power test observe the working state of the amplifier at the max input power It...

Страница 21: ...Non harmonic Suppression Test a Testing equipment Signal source S1465 1 Spectrum analyzer 4036 1 High power attenuator 89 30 21 1 b Testing diagram Figure 5 3 Diagram of the non harmonic suppression t...

Страница 22: ...lifier itself first Before the test check whether the accessories connected with the solid state power amplifier and the interfaces between them are normal to ensure that the problem is not caused by...

Отзывы: