17
Tel: 886.2.2175 2930 Email: [email protected]
:CALCulate:MARKer[n]:CPEak[:STATe]
Command Format
:CALCulate:MARKer[n]:CPEak[:STATe] ON|OFF|0|1
:CALCulate:MARKer[n]:CPEak[:STATe]?
Description
Set or inquire the status of continuous peak function
Note
0|OFF disable
1|ON enable
[n] is available 1~5
:CALCulate:NETMeasure[:STATe]
Command Format
:CALCulate:NETMeasure[:STATe] ON|OFF|0|1
:CALCulate:NETMeasure[:STATe]?
Description
Set or inquire the status of network measurement
Note
0|OFF disable
1|ON enable
:CALCulate:NETMeasure:RLEVel
Command Format
:CALCulate:NETMeasure:RLEVel <ampl>
:CALCulate:NETMeasure:RLEVel?
Description
Set or inquire the reference level of network measurement
Note
<ampl> is available -80dB~+30dB
:CALCulate:NETMeasure:POWer
Command Format
:CALCulate:NETMeasure:POWer <ampt>
:CALCulate:NETMeasure:POWer?
Description
Set or inquire the output power of network measurement
Note
<ampt> is available -30dB~0dB
:CALCulate:NETMeasure:NORMalize
Command Format
:CALCulate:NETMeasure:NORMalize
Description
Normalize the network measurement result
Note