SALTO Systems - SALTO Geo user manual
9
CONFIDENTIAL - This document contains confidential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.
PROGRAMMING
To grant or deny access permissions are used the right SW license. Once you update the system
configuration:
- ROM System updates the access permissions on the cylinders using a PPD.
- RW System is not necessary to update the cylinders with the PPD. The system allows elec-
tronic cylinders to read, receive and write information via its operating smart cards or ‘intelligent’
keys. This data is captured from the cards at SVN on-line hot spots located at strategic points
around the building.The “online points” uploads and downloads user related information that is
then used to permit, control or deny access.
BATTERIES
Low battery status.
The low battery status can be recognised by 4 slow and low pitched warning tones. If these war-
nings are ignored then the batteries will fail.
Battery failure.
In the case of complete battery failure the product fails both safe and secure, i.e. the outside
handle fails “locked” to avoid intrusions, the inside handle fails “open” to permit emergency
openings. Note that once the cylinder is powered again with new batteries all the keys that were
programmed into the cylinder will still work as before, because the memory is retentive.
WARNING:
The electronic cylinders needs to be updated with the PDD to recover the hour.
“The product should not be modified in any way except in accordance with those modifications
described in the instructions”