2.1 Dimensions
The diameter and height dimensions of the flush mounted volumetric sensor are shown
in the following images.
2.2
Installation process
The flush mounted volumetric sensor should be installed in the following order:
1. Mark the position of the hole to be drilled.
2. Drill a hole with a 75mm crown.
3. Synchronise the sensor and the Energy Saver.
Present the Sensor Synchronising Card on the energy saver which will then
remain in synchronisation mode until the card is removed again.
Press the Sensor’s internal pushbutton with your hand while the Sensor Syn
chronising Card is on the energy saver. The red pilot light will come on.
The sensor and the energy saver will then try to synchronise. Synchronisation
is correct when the red sensor flashes very quickly for about five seconds. The
red pilot light must go off then.
Repeat the same procedure with all the sensors in the same room that must be
synchronised with the same energy saver.
Remove the card from the energy saver once all sensors have been synchroni
sed.
4. Position the flush mounted volumetric sensor in the ceiling and secure it using the
two tabs.
37cm
66 cm
85cm