background image

02/18/04

5

Configuration

All Serial Communication parameters are em-

bedded in a user menu consisting of 5 separate

menu selections, each with its own sub-menu of

choices. If your scale is connected by RS-232

serial communication lines to other equipment,

or you wish to disable the 

lb/kg

 key, you may

have to modify some or all of these parame-

ters. To modify these parameters, you must first

enter the USER MENU mode. Once there, four

of the front panel keys become directional navi-

gators to move around in the menus, and one

key is used to save or SET the selections. Com-

plete directions are found below.

To place the unit in USER MENU mode:

Turn the scale off.

While holding down the 

lb/kg

key, turn the scale back on.
When the display shows "

A1

",

the unit is in USER MENU mode,

and you can release the 

lb/kg

key. Shown at right are the

directional and SET key assign-

ments.

Zero

Gr

Net

lb

kg Motion

Tare

MODEL

SPD100

TRANSTRONIC SCALE CO.

CLASS

CAPACITY :

100x0.05 lb

50x0.02 kg

n

max=3000

SET

USER MENU CHART

A2

A3

A4

A5

A1

Baud Rate

Data Bits,

Parity

Transmission

Mode

Serial Data Format

Disable Lb/kg

Key

c

d

0

1

8

7O

7E

7

0

1

2

3

4

1200

2400

4800

9600

To place the unit back into the NORMAL OPERATING mode, turn off the power to the unit.

With no keys held down, turn the power back on. All front panel keys will now return to

their normal mode of operation.

SETTINGS FOR USE WITH UPS ONLINE AND ONLINE OFFICE SOFTWARE

A1 = 9600
A2 = 7 o
A3 = don’t care

A4 = 4
A5 = 0

Содержание SP series

Страница 1: ...h Scale Revision 8 93 August 12 1993 Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont MN 56031 Tel 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 E mail sales salterbrecknell com Web w...

Страница 2: ...02 18 04 2 Table of Contents Introduction 1 Installation and Wiring 1 Keyboard Functions 1 Configuration 2 User Menu Descriptions 2 Calibration 3 Specifications 4 Warranty and Service Information 5...

Страница 3: ...p are found in the Configura tion section of the manual Installation and Wiring Unless you wish to interface to a device other than a PC no wiring is necessary Simply con nect the indicator to the sca...

Страница 4: ...between Gross and Net weight display Zero Gr Net lb kg Motion Zero Net Gross Tare Print Tare MODEL SPD100 TRANSTRONIC SCALE CO CLASS CAPACITY 100x0 05 lb 50x0 02 kg kg lb nmax 3000 SP SERIES FRONT PA...

Страница 5: ...USER MENU mode Turn the scale off While holding down the lb kg key turn the scale back on When the display shows A1 the unit is in USER MENU mode and you can release the lb kg key Shown at right are...

Страница 6: ...he printer computer or indicator C d A4 Serial Data Format Selects the data format to be transmitted via the serial port to a printer or computer 0 Consolidated Controls Format 1 Toledo 8213 Format 2...

Страница 7: ...ue to the actual test weight value in pounds Increase the flashing digit by pressing the lb kg key Decrease the flashing digit by pressing the ZERO key The position of the flashing digit may be change...

Страница 8: ...OPERATING TEMPERATURE RANGE 32 F to 104 F 0 C to 40 C OPTIONAL SWIVEL POST 12 30mm Tall Stainless Steel Construction POWER SOURCE AC Adapter 12VDC 650mA included WEIGHT Net Weight 19 4 lb 8 8 kg Ship...

Страница 9: ...13 2in 336 00mm 10 2in 258 00mm 3 8in 97 50mm ON OFF SWITCH DC POWER JACK RS 232 PORT INDICATOR CONNECTOR ID TAG CALIBRATION SWITCH COVER BASE...

Отзывы: