background image

FUNCTION KEYS                                                                       

The Model 7010SB has three function keys to operate the scale.  They are

ON/OFF (TARE), WT HOLD, and LB-OZ/ GRAMS.

ON/OFF  (TARE) KEY:

The ON/OFF (TARE)  key performs three functions.  First it applies power to the

scale; second it tares the weight on the scale to zero; third it will turn off the scale.

To use the “tare” feature:

1. Place an empty container on the weighing platform.

2. Press the ON/OFF (TARE) key.  The scale will display zero weight.

3. When an item is placed on the container, the scale only displays the weight of

the item, not the weight of the container.

4. To reset the scale for no tare, remove the container and its contents from the

weighing platform.  Press the ON/OFF (TARE) key, then to reset the scale to

zero weight.

The tare function will work over the full weighing range of the scale but will not

extend the overall capacity of the scale.

Important Note: It is recommended to press the “ON/OFF (TARE) key” before

placing an item on the scale.  This will help ensure accurate weight readings.

To turn off the power to the scale:

1.  Press and hold the ON/OFF (TARE) key for 5 seconds.  The display will no

longer show any weight, indicating the scale is powered off.

LB-OZ/ GRAMS:

The LB-OZ GRAMS key is to switch between weighing lb-oz and grams, it is also

used for entering into the calibration mode.

ZERO THE SCALE:

The proper method of zeroing the scale is to press the “ON/OFF (TARE)” key.

3

MODEL 7010SB TECHNICAL SPECIFICATIONS                       

Construction:  ABS Plastic

Capacity:

0-5lb. 8oz  x 0.1 oz. / 5lb 9oz -9lb x 15.5oz x 0.5oz

0-2500g x 5g  / 2501-5000 x 10g  (grams mode)

Accuracy:

+/- 2 divisions (0.2oz / 10g) / (1.0oz/ 20g)

Display:

Large LCD

Unit Size:

8”W x 7.5”L x 2”H

Platter Size:

8”W x 5”L

Keypad:

Membrane switch with ON/OFF (Tare), WT HOLD and LB-OZ/

GRAMS.

Power Supply: 120 VAC, 60Hz Ac adapter with 6’ power cord or 9 volt battery

(battery not included)

CLEANING AND CARE                                                             

1.  Handle the scale with care.  Dropping the scale may cause damage to the

loadcell, which will not allow the scale to weigh properly.  This type of damage is

considered abuse and violates the product warranty.

2.  To avoid damage to the loadcell, never place objects on the scale that exceed 10

pounds.

3.  Clean the scale with a slightly damp cloth.  DO NOT immerse the scale in water

or use chemical/abrasive-cleaning agents.

4.  If the scale is not being used for a long period of time, remove the battery or turn

off the scale.

WARRANTY                                                                         

This product has a 

90-day

 warranty from the date of delivery against defects in

material and workmanship.  This warranty does not apply if the product was subject

to misuse, neglect, damage or abuse. Calibration is not covered under warranty.

8

Отзывы: