7 Installation and electrical connection
DANGER! Danger of death!
Incorrect installation and inexpert electrical connection can pose a risk of
fatal injury. Danger from electrical current must be eliminated.
• The installation and electrical connection may only be carried out by quali-
fied personnel in accordance with the applicable regulations!
• Accident prevention regulations must be observed!
• Comply with the regulations of the local power supply company!
Pumps with pre-assembled cable:
• Never pull on the pump cable
• Do not kink the cable.
• Do not place any objects on the cable
7.1 Installation
WARNING! Danger of personal injury!
Incorrect installation can result in personal injury.
• There is a crush hazard
• There is an injury hazard due to sharp edges/burrs. Wear appropriate protec-
tive clothing (e.g. safety gloves)!
• There is an injury hazard due to the pump/the motor falling. Use suitable lift-
ing gear to secure the pump/motor against falling.
CAUTION! Risk of damage!
Incorrect installation can result in damage to the product.
• Only use qualified personnel for the installation work!
• Observe national and regional regulations!
• When the pump needs to be transported, it may be carried only by the motor/
pump housing. Never carry it by the module/terminal box!
• Installation within a building
• Install the pump in a dry, well-ventilated room. Ambient temperatures below
-20 °C are not permitted.
• Installation outside a building (outdoor installation):
• Install the pump in a sump (e.g. light sump, annular sump) with cover or in a
cupboard/housing as weather protection. Ambient temperatures below -20 °C
are not permitted.
• Exposure of the pump to direct sunlight must be avoided.
• The pump requires protection so that the condensate drain grooves are not
contaminated (fig. 8).
• Protect the pump against rain. Dripping water from above is permitted pro-
vided that the electrical connection has been established in accordance with
the installation and operating instructions and has been properly sealed
CAUTION! Risk of damage!
Ensure sufficient ventilation/heating if the ambient temperature exceeds/
falls below the permitted limit values.
• Carry out all welding and soldering work prior to the installation of the pump.