ENGLISH
13
10.FAULTS, THEIR CAUSES AND REMEDIES
If the fault can't be fixed, please contact your local specialist
or your nearest Salmson customer service location or repre-
sentative.
11.SPARE PARTS
Spare parts can be ordered from your local specialist and/or
via Salmson
customer service.
To avoid queries and incorrect orders, always provide all of the
details on the name plate with every order.
We reserve the right to make technical changes!
FAULT
CAUSE
REMEDY
THE PUMP WON'T START OR
STOPS DURING OPERATION
Interruption to the power
Check fuses, cables and electrical connections
Motor protection switch has tripped
Allow the pump to cool down; it will restart auto-
matically
The temperature of the pumped liquid is too
high
Allow to cool down
Pump is silted up or seized
Remove power from the pump and pull it out of
the shaft
Remove the suction basket and wash down the
suction basket and impeller under running water
THE PUMP DOESN'T TURN ON/
OFF
Float switch is jammed or cannot move freely
Check the float switch and make sure that it can
move freely
THE PUMP DOESN'T PUMP PROP-
ERLY
Air in the system can't escape
Bleed air from the system, emptying if necessary
Check the switch off level
The water level is below the suction opening
If possible, submerse the pump more deeply
(note switch-off level)
The non-return valve in the pump port is stick-
ing
Check that it is working properly
Kink in the hose / Stop valve closed
Unkink the hose / open the stop valve
THE FLOW RATE DECREASES DUR-
ING OPERATION
The suction basket is blocked / the impeller is
jammed
Remove power from the pump and pull it out of
the shaft
Dismantle the suction basket, wash down suction
basket / impeller under running water.