2.  SAFETY INFORMATION.

2.1.  USING THIS MANUAL.

The documentation of any standard equipment is available to 

the customer on our website for download 

(www.salicru.

com)

.

 

For devices “powered by socket”, this is the website for 

obtaining the user manual and 

“Safety Instructions”

 

EK266*08.

 

For devices with “permanent connection” via terminals, a 

CD-ROM or pen drive containing all necessary information 

for connection and start-up, including 

“Safety Instruc-

tions”

 EK266*08, may be supplied with it.

Before carrying out any action on the device relating to its 

installation or start-up, change of location, configuration or 

handling of any kind, carefully read the safety instructions.

The purpose of the user manual is to provide information 

regarding safety and explanations of the procedures for 

installation and operation of the equipment. Read them carefully 

and follow the steps indicated in the order established.

 

Compliance with the "Safety Instructions" is 

mandatory and the user is legally responsible

 for 

compliance and enforcement.

The equipment is delivered properly labelled for the correct 

identification of each of the parts, which together with the 

instructions described in this user manual allows the operations 

of installation and commissioning to be performed in a simple 

and orderly manner without having any doubts whatsoever.

Finally, once the equipment is installed and operating, it is 

recommended to save the documentation downloaded from the 

website, CD-ROM or Pen Drive in a safe and easy-to-access 

place, for any future queries or doubts that may arise.

The following terms are used interchangeably in the document 

to refer to:

 

«Manual bypass, Bypass, equipment or unit»

.- Rack 

mounting manual bypass.

 

«T.S.S.»

.- Technical Service and Support.

 

«Client, installer, operator or user»

.- These are used 

interchangeably and by extension to refer to the installer 

and/or operator who will carry out the corresponding 

actions, and the same person may be responsible for 

carrying out the respective actions when acting on behalf 

of, or in representation of, same.

2.1.1.  Conventions and symbols used.

Some symbols may be used and appear on the equipment, 

batteries and/or in the context of the user manual.

For more information, see section 1.1.1 of document EK266*08 

on 

«Safety instructions»

.

2.2.  ADDITIONAL SAFETY PRECAUTIONS.

 

In the point of view of installation and electrical safety, 

the rack mounting manual bypass must be considered as a 

transformer or distribution line.

 

As this is an equipment with protection against electrical 

shocks class I, it is essential to supply or install the main 

protection earth cable 

( )

, through either the AC wall 

outlet or corresponding terminal.

 

Those models with terminals, they have to be in-

stalled 

by both qualified personnel and per-

sonnel with particular training

 which can make the 

shifting manoeuvring with the help of this document.

 

The instructions that being read are relating to the own 

manual bypass only. Any other action related to this docu-

ment, which involves any manoeuvring over any other 

equipment like a UPS or stabilizer, it will be done as its 

user’s manual states.

 

The neutral regime from input to output is identical for the 

bypass panels “with no galvanic isolation”. The neutral re-

gime must always be the same for the manual bypass as 

well as the UPS or stabilizer.

BM-R 

Rack mounting manual bypass

 

 

USER'S MANUAL        

Содержание BM-R 10

Страница 1: ...USER S MANUAL RACK MOUNTING MANUAL BYPASS BM R 3 6 and 10 kVA...

Страница 2: ...2 SALICRU...

Страница 3: ...and contents 6 2 LOCATION AND CONSIDERATIONS 6 2 1 1 Location 6 3 WIRING 7 OPERATING 7 1 START UP 7 2 TRANSFERENCE FROM NORMAL OR UPS MODE TO BYPASS 7 2 1 3 kVA manual bypass models from NORMAL to BYP...

Страница 4: ...ed personnel Although no effort has been spared to ensure that the information in this user manual is complete and accurate we are not responsible for any errors or omissions that may exist The images...

Страница 5: ...rms are used interchangeably in the document to refer to Manual bypass Bypass equipment or unit Rack mounting manual bypass T S S Technical Service and Support Client installer operator or user These...

Страница 6: ...ercialized in accordance with the standard EN ISO 9001 of Quality Management Systems and certified by SGS body The marking shows the conformity to the EEC Directive by means of the application of the...

Страница 7: ...y IEC connector or input terminals 2 To be connected to the UPS or stabilizer input 3 To be connected to the UPS or stabilizer output 4 IEC connectors or output terminals to loads 5 Main protective ea...

Страница 8: ...onnection with the sup plied cable between this connector and the one available in several equipments like the UPS from TWIN PRO2 and or RT2 series when the protecting cover from manual bypass is remo...

Страница 9: ...TION AND CONSIDERATIONS 6 2 1 1 Location Remove the angles and screws from the plastic bag and assemble them on the rack mounting bypass These devices are designed to be integrated into rack cabinets...

Страница 10: ...ing on its power rate Respect the stated input and output strictly other wise the UPS or stabiliser manual bypass and loads can be damaged As this is an equipment with protection against electrical sh...

Страница 11: ...the UPS or stabilizer have not been transferred to Bypass mode when the protection cover 13 is removed the equipment will shift to this operating mode automati cally provided that the bypass signal 10...

Страница 12: ...fix an hypothetical failure the procedure formality will be smoother 8 2 2 Out of scope of supply In case it is detected that the product is not damaged or the fault was caused by a wrong manoeuvring...

Страница 13: ...ximum permissible current of the manual bypass switch 16 A 40A 63A Selective output breakers IEC connectors 2 Maximumpermissiblevoltageoftheoutputbreakers 250 V Output breaker size 10 A Number of outp...

Страница 14: ...14 SALICRU...

Страница 15: ...15 BM R Rack mounting manual bypass USER S MANUAL...

Страница 16: ...alicru_SA Product Range Uninterruptible Power Supplies UPS Lighting Flow Dimmer Stabilisers DC Power Systems Static Inverters Photovoltaic Inverters Voltage stabilisers Variable frequency drives The T...

Отзывы: