56
| EN
SMARTY v2023.1
Climate
zone
SMARTY
3X V 1.1
SMARTY
3X V 1.1 E
SMARTY
3X V 1.2
SMARTY
3X V 1.2 E
SMARTY
3X V S300
SMARTY
3X V S300 E
Average
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-42,7
-41,3
-39,4
-37,6
-39,4
-37,6
SEC Class
A+
A
A
A
A
A
AEC
[ kWh/a ]
189
189
291
289
291
289
AHS
[ kWh/a ]
4672
4532
4602
4418
4602
4418
Cold
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-82
-79,3
-78,1
-74,5
-78,1
-74,5
SEC Class
A+
A+
A+
A+
A+
A+
AEC
[ kWh/a ]
726
726
828
826
828
826
AHS
[ kWh/a ]
9141
8866
9003
8644
9003
8644
Warm
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-17,5
-16,9
-14,7
-13,9
-14,7
-13,9
SEC Class
E
E
E
E
E
E
AEC
[ kWh/a ]
144
144
246
244
246
244
AHS
[ kWh/a ]
2113
2049
2081
1998
2081
1998
Topology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Recovery type
Recuperative
Recuperative
Recuperative
Recuperative
Recuperative
Recuperative
Type of drive (fan)
Variable
Variable
Variable
Variable
Variable
Variable
7KHUPDOHႈFLHQF\
>@
89
82,2
89
82,2
89
82,2
0D[LPXPDLUÀRZ
[ m
3
/h ]
409
409
409
409
409
409
)DQSRZHUDWPD[DLUÀRZ
[ W ]
177
177
177
177
177
177
&DVLQJVRXQGSRZHUOHYHO/ZD
[ dB(A) ]
49
49
49
49
49
49
5HIHUHQFHDLUÀRZ
[ m
3
/s ]
0,08
0,08
0,08
0,08
0,08
0,08
Reference pressure
[ Pa ]
50
50
50
50
50
50
SPI
[ W/(m
3
/h) ]
0,27
0,27
0,27
0,27
0,27
0,27
Control factor
0,65
0,65
0,85
0,85
0,85
0,85
Declared maximum internal
leakage rates
>@
1,2
1,2
1,2
1,2
1,2
1,2
Declared maximum external
leakage rates
>@
1,2
1,2
1,2
1,2
1,2
1,2
9LVXDO¿OWHUZDUQLQJ
Timer
Timer
Timer
Timer
Timer
Timer
ErP Compliance
2018
2018
2018
2018
2018
2018
Internet address for disassembly instructions
https://select.salda.lt
Climate
zone
SMARTY
4X P F2 1.1
SMARTY
4X P 1.1 E
SMARTY
4X P F2 1.2
SMARTY
4X P 1.2 E
SMARTY
4X P S300
SMARTY
4X P S300 E
Average
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-40,6
-37,9
-36,3
-32,8
-36,3
-32,8
SEC Class
A
A
A
B
A
B
AEC
[ kWh/a ]
224
224
351
352
351
352
AHS
[ kWh/a ]
4548
4286
4440
4096
4440
4096
Cold
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-78,7
-73,5
-73,4
-66,6
-73,4
-66,6
SEC Class
A+
A+
A+
A+
A+
A+
AEC
[ kWh/a ]
761
761
888
889
888
889
AHS
[ kWh/a ]
8898
8384
8686
8013
8686
8013
Warm
6SHFL¿FHQHUJ\FRQ
-
sumption (SEC)
[ kWh/m
2
a ]
-16,1
-14,9
-12,4
-10,9
-12,4
-10,9
SEC Class
E
E
E
E
E
E
AEC
[ kWh/a ]
179
179
306
307
306
307
AHS
[ kWh/a ]
2057
1938
2008
1852
2008
1852
Topology
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Bidirectional
Recovery type
Recuperative
Recuperative
Recuperative
Recuperative
Recuperative
Recuperative
Type of drive (fan)
Variable
Variable
Variable
Variable
Variable
Variable