6
| EN
SMARTY RV v2019.12
- power/current
[kW/A]
0,006/0,1
0,006/0,02
#<
>?@
>?@
Heater
- power/current
[kW/A]
0,6/2,61
0,6/2,61
Exhaust air fan
- phase/voltage
[f/VAC/Hz]
~1/230/50
~1/230/50
- power/current
[kW/A]
0,07/0,6
0,084/0,75
- speed
[min
-1
]
1380
3200
- protection class
IP44
IP54
- control imput
[VDC]
0-10
0-10
Supply air fan
- phase/voltage
[f/VAC/Hz]
~1/230/50
~1/230/50
- power/current
[kW/A]
0,07/0,6
0,084/0,75
- speed
[min
-1
]
1380
3200
- protection class
IP44
IP54
- control imput
[VDC]
0-10
0-10
Total
- power/current
[kW/A]
0,75/3,91
0,77/4,13
Automatic control integrated
+
+
Insulation of walls
[mm]
20
20
Weight
[kg]
36
36
class class
_`{}??@
_`{}?@
width
[mm]
270
270
height
[mm]
86
85
depth
[mm]
46
173
model
MPL
FMK
class
_`{}??@
_`{}?@
width
[mm]
270
270
height
[mm]
86
85
depth
[mm]
46
173
model
MPL
FMK
SMARTY 2R VER
LWA TOTAL,
DB(A)
LWA, DB(A)
63 Hz
125 Hz
250 Hz
500 Hz
1 kHz
2 kHz
4 kHz
8 kHz
Outdoor
62
22
54
61
48
41
27
20
14
Supply 70
29
61
68
59
60
55
49
43
Extract
62
22
54
61
49
36
28
19
14
Exhaust
69
28
60
67
58
58
52
48
41
Surrounding
49
10
40
48
36
31
30
30
29
Measured at 140 m
3
/h, 50 Pa
SMARTY 2R VER PLUS
LWA TOTAL,
DB(A)
LWA, DB(A)
63 Hz
125 Hz
250 Hz
500 Hz
1 kHz
2 kHz
4 kHz
8 kHz
Outdoor
60
18
50
58
55
44
28
16
12
Supply 66
23
55
63
61
56
55
48
40
Extract
60
19
50
58
54
40
35
24
17
Exhaust
66
23
55
62
60
56
53
46
36
Surrounding
48
3
34
44
45
32
31
30
29
Measured at 180 m
3
/h, 50 Pa
NOTE
!