background image

58 

| EN

RIRS 1200-5500 V EKO 3.0 v2019.06

24.  WARRANTY

1. All equipment manufactured in our factory is checked in operating conditions and tested befor delivery. Test protocol is supplied together with 

the unit. The equipment is shipped in good working order and condition to the direct client. The unit is warrantied for the period of two years from 

the invoice date.

2. If equipment is found to have been damaged during transportation, a claim should be made against carrier, as we assume no responsibility for 

such damage.

3. This warranty does not apply:

3.1. when transportation, storage, installation and maintenance instructions of the unit are violated;

3.2. when the equipment is improperly maintained, mounted - inadequate maintenance; 

3.3. when the equipment without our knowledge and permission has been upgraded or unskilled repairs were made;

3.4. when the unit was used not for its original purpose.

3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a 

control system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that 

will be damaged by installing the control system.

4. This warranty does not apply at these malfunction cases:

4.1. mechanical damage; 

4.2. damage caused by entering outside objects, materials, liquids; 

4.3. damage caused by natural disaster, accident (voltage change in the electricity network, lightning, etc..).

5. The company assumes no liability for its products either directly or indirectly damage, if the damage is caused by failure to comply with instal-

lation and mounting regulations, deliberate or careless users or third-party behavior.

These conditions are readily discernable when the equipment is returned to our factory for inspection.

If the direct client determines that equipment is found to be faulty, or a breakdown occurred, he should inform the manufacturer within five working 

days and deliver the equipment to manufacturer. Delivery costs should be covered by customer.

Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic 

errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be 

included in the new issues of the technical passport. All illustrations are just for information and thus may differ from the 

original device.

24.1.   LIMITED WARRANTY COUPON

Warranty term

24 months*

I received complete package and technical manual of the product ready for usage. I have read warranty terms and conditions and agree with them: 

 

..........................................................................................................................................................................

Customer’s signature

*refer to WARRANTY CONDITIONS

Dear User, we appreciate your choice and do hereby guarantee that all ventilation equipment manufactured by our Company is inspected and 

thoroughly tested. An operational and high-quality product is sold to the direct buyer and shipped from the territory of the factory. It is provided with 

a 24-month warranty since invoice issue date.

Your opinion is important to us, thus we always look forward to hearing your comments, feedback, or suggestions regarding technical and opera-

tional characteristics of the Products.

In order to avoid any misunderstandings, please read the instructions for installation and operation of the product as well as other technical docu-

ments of the product carefully. The number of the Limited Warranty Coupon and serial number of the product specified on the silver identification 

sticker attached to the housing must match. 

The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is prohibited to change, delete, or rewrite 

the data specified on it in any manner – such a coupon shall be invalid.

With this Limited Warranty Coupon the manufacturer confirms one’s obligations to implement the imperative requirements established by effective 

laws on protection of consumer rights in the event of identification of any defects of the products.

The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disre-

garded.

Содержание RIRS 1200 V EKO 3.0

Страница 1: ...RIRS 1200 5500 V EKO 3 0 EN MOUNTING AND INSTALLATION INSTRUCTION...

Страница 2: ...OF THE HVAC UNIT 17 19 5 SYSTEM ADJUSTMENT GUIDELINES 17 20 CONTROL BOARD RG1 19 20 1 LABELING CHARACTERISTICS OF THE CONTROLLER AND THE SYSTEM COMPONENTS 20 20 2 REGULAR SYSTEM CHECK UP 21 21 ELECTRI...

Страница 3: ...quency Max current Max power consumption Protection class Weight xxx xx VAC Hz x xx A x xx kW IP xx xx kg Made in iauliai Lithuania AHU000000 BN xxxxxx 2019 01 01 SERIAL 2514523357 XXX GAMINIO PAVADIN...

Страница 4: ...ked check the grounding make sure that all components and accessories are connected in accordance with the project or provided instructions Danger Fumes Salda Antifrost system uses dis balancing of th...

Страница 5: ...m 50 50 50 50 Cross section of the power supply cable mm 4x2 5 4x2 5 3x1 5 3x1 5 Circuit breaker Poles 2 2 1 1 I A B16 B16 B10 B10 Filter class and dimensions exhaust mm 745x350x46 745x350x46 745x350x...

Страница 6: ...er class and dimensions exhaust mm 790x400x46 790x400x46 900x455x90 900x455x90 supply mm 790x400x46 790x400x46 900x455x90 900x455x90 RIS EKO 3 0 5500 VE 5500 VW Heater phase voltage 50 Hz VAC 3 SVS po...

Страница 7: ...pocket 9 Rotor engine 7 OPERATING CONDITIONS 5 C o 40 C o 40 C o 40 C o 15 C o 40 C o 3 C o 40 C o 5 C o 40 C o 23 C o 40 C o 15 C o 40 C o 40 C 23 C o O 40 C 15 C O O RH 60 40 C 23 o C O Ex O O 40 C...

Страница 8: ...the unit first unpack the accessories Remove the film from the unit Remove the bracing packaging tape which keeps the protective profiles Remove the protective profiles After unpacking the unit examin...

Страница 9: ...1 5xL H Min distance to open the door 1 5xL Min distance to open control box door H 400 mm 13 MOUNTING The protective film is intended to protect the unit during transportation It is recommended to re...

Страница 10: ...duct conection Figure 14 2 Rectangular air duct conection D2 dimensions depend on unit 15 CONNECTION DIAGRAM PS PS PS PS 2 2 2 2 Figure 15 1 RIRS 1200 1900 VE EKO 3 0 Placement of the component depen...

Страница 11: ...ns speed switch BOOST Component posibility to connect it depends on model For more information please check the manual 16 CONNECTION OF THE UNIT TO ELECTRIC NETWORK Supply voltage to the unit must be...

Страница 12: ...ters are clogged and no message is shown on the remote control Wrong time in filter timers or their switch is broken or its pressure is set improperly Shorten filter timer time till the message of clo...

Страница 13: ...can harm the heat exchanger It is NECESSARY to protect the motor of the heat exchanger from the moisture and liquid while cleaning the heat exchanger CAUTION It is forbidden to use the heat exchanger...

Страница 14: ...using the START STOP feature STOP is displayed at the remote control panel FLEX In START mode the recuperator operates based on the latest settings of the panel FanFail and FanRun features It provides...

Страница 15: ...rotection is triggered fans operate in maximum capacity until the manual heater protection is reset by pressing the reset button and the device is restarted When heater fault is registered manual heat...

Страница 16: ...Read_Coils 10 1 Return water temperature sensor alarm 1 a c t i v e o passive 11 ToutDoor 01h_Read_Coils 11 1 Outside air temperature sensor alarm controller continues to work in determining ToutDoor...

Страница 17: ...ted place Install the supplied connection cable FLEX controller between the control panel and the HVAC unit It is recommended to install the control panel separately from the power cables Note If cabl...

Страница 18: ...rm input damper actuator damper actuator Extract air Supply air L L control N L control ON OFF ON OFF 230V AC 230V AC 15 20 16 L L N N L 18 17 M3 M2 X16 5 19 L N 17 16 15 14 13 12 11 X16 6 22 21 temp...

Страница 19: ...a LED2 Air damper close LED9 Medium fans speed LED2 LED3 Air damper open LED10 Minimal fans speed LED4 Water valve open LED11 Supply air fan speed reducing LED5 Water valve close LED12 Preheater LED6...

Страница 20: ...X32 3 HIGH BOOST increase the flow of air I X32 4 COM COM X33 1 TIMER Stop DI X33 2 COM COM M5 Water cooler valve actuator X33 3 VAL Cooling valve opening PWM 24v 50hz AO X33 4 VAL Cooling valve closi...

Страница 21: ...ture sensor AI X39 2 COM TE Exhaust air temperature sen sor X41 1 Exhaust air temperature sensor AI X41 2 COM PV Supply air fan X37 1 V1 Supply air fan 0 10V AO X37 2 COM COM IV Extract room s air fan...

Страница 22: ...7 18 L N N L L 20 L supply 230V AC 230V AC ON OFF ON OFF L X37 TL N PE L1 1 3 4 2 LOW X32 1 COM X32 4 HIGH X32 2 TIMER X32 3 COM X33 1 MID X33 2 CHIL X33 9 COM X33 10 BOOST STOP NO START NC A2 A1 R1 8...

Страница 23: ...3 X38 2 X38 1 28 27 26 X33 24 X33 23 COM T set 26 24V DC 27 intput 0 10V DC 28 GND Transmitter 2 24 VDC P 29 X16 7 30 31 1A 2 1 F3 N L M4 PE 1f 230V AC 32 X16 8 33 34 24VDC 0 10VDC M6 G Y 0 0 GND Y 0...

Страница 24: ...24 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 3 RIRS 1900 VE EKO 3 0...

Страница 25: ...EN 25 RIRS 1200 5500 V EKO 3 0 v2019 06 21 4 RIRS 1900 VW EKO 3 0...

Страница 26: ...26 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 5 RIRS 2500 3500 VE V2 4 RHX 0K...

Страница 27: ...EN 27 RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 28: ...28 EN RIRS 1200 5500 V EKO 3 0 v2019 06 ModBus RTU...

Страница 29: ...EN 29 RIRS 1200 5500 V EKO 3 0 v2019 06 21 6 RIRS 5500 VE V2 4 RHX 0K...

Страница 30: ...30 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 31: ...EN 31 RIRS 1200 5500 V EKO 3 0 v2019 06 ModBus RTU...

Страница 32: ...32 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 7 SVR 2500VE 9 3F V2 4 2K...

Страница 33: ...EN 33 RIRS 1200 5500 V EKO 3 0 v2019 06 21 8 SVR 3500VE 9 ESKM 0K 3X230...

Страница 34: ...34 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 9 SVR 5500VE 18 3F ESKM 0K...

Страница 35: ...EN 35 RIRS 1200 5500 V EKO 3 0 v2019 06 21 10 RIRS 2500VE V2 4 RHX 0K...

Страница 36: ...36 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 37: ...EN 37 RIRS 1200 5500 V EKO 3 0 v2019 06 21 11 RIRS 3500VE V2 4 0K RHX 3X230...

Страница 38: ...38 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 39: ...EN 39 RIRS 1200 5500 V EKO 3 0 v2019 06 21 12 RIRS 5500VE V2 4 RHX 0K...

Страница 40: ...40 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 41: ...EN 41 RIRS 1200 5500 V EKO 3 0 v2019 06 21 13 RIRS 2500 3500 VW V2 4 RHX 0K...

Страница 42: ...42 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 43: ...EN 43 RIRS 1200 5500 V EKO 3 0 v2019 06 ModBus RTU...

Страница 44: ...44 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 45: ...EN 45 RIRS 1200 5500 V EKO 3 0 v2019 06 21 14 RIRS 5500 VW V2 4 RHX 0K...

Страница 46: ...46 EN RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 47: ...EN 47 RIRS 1200 5500 V EKO 3 0 v2019 06 ModBus RTU...

Страница 48: ...48 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 15 RIRS 2500 VW V2 4 RHX 0K...

Страница 49: ...EN 49 RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 50: ...50 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 16 RIRS 3500 VW V2 4 RHX 0K...

Страница 51: ...EN 51 RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 52: ...52 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 17 RIRS 5500 VW V2 4 RHX 0K...

Страница 53: ...EN 53 RIRS 1200 5500 V EKO 3 0 v2019 06 21 18 RIRS 2500 VW R3G280 AU06 B1...

Страница 54: ...54 EN RIRS 1200 5500 V EKO 3 0 v2019 06 21 19 RIRS 3500 VW RH35C ZID DC 1R 21 20 RIRS 5500 VW R3G 400 AY87 01...

Страница 55: ...nerative regenerative regenerative Thermal efficiency of heat recovery 73 73 73 73 Nominal NRVU flow rate m3 s 0 41 0 41 0 41 0 41 Effective electric power input kW 0 83 0 83 0 83 0 83 SFPint W m3 s 7...

Страница 56: ...40 2 40 2 42 8 42 8 50 3 50 3 Declared maximum external leakage 1 1 1 1 1 1 Declared maximum internal leakage 3 3 3 3 3 3 Energy clasification of the filters E E E E E E Description of visual filter...

Страница 57: ...sk reduction LST EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General...

Страница 58: ...iver the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic erro...

Страница 59: ...59 RIRS 1200 5500 V EKO 3 0 v2019 06...

Страница 60: ...NANCE TABLE Product name LOT number Instalation Interval Datum Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE...

Отзывы: