5.1. RECEPTION OF GOODS
Each device is thoroughly checked before transportation. When receiving goods it is recommended to check whether devices were damaged
during transportation. If damage to the device is identified, immediately inform the representatives of a transport company. Please inform a rep
-
resentative
of the manufacturer, if any deviation from the order is noticed.
5.2. TRANSPORTATION AND STORAGE
•
All units are packed in the factory to withstand regular conditions of transportation.
• The package is only for protection purpose!
•
When unloading and storing the units, use suitable lifting equipment to avoid damage or injuries. Do not lift units by holding on power supply
cables, connection boxes, air extract or exhaust flanges. Avoid impact and shock overloads. Before installation units must be stored in a dry
room with the relative air humidity not exceeding 70% (at +20 °C) and with an average ambient temperature ranging b5 °C and +30
°C. The place of storage must be protected against dirt and water.
• The units must be transported to the storage or installation site using forklifts.
• The storage is not recommended for a period longer than one year. In case of storage longer than one year, before the installation it is neces-
sary to verify whether the bearings of fans and motor rotate easily (turn the impeller by hand) and if the electric circuit insulation is not damaged
or the moisture is accumulated.
•
AmberAir Compact are lifted from the pallet with a forklift or slings, which are inserted through the supporting legs (four corners).
•
AmberAir Compact are lifted from the pallet with a forklift at the recesses at the supporting base, or with slings.
When lifting with a forklift, protect the condensate drainage pipes. The product is heavy. Exercise caution when transporting
and installing.
W/W*
AMBERAIR COMAPCT
H
W
L1
L2
L3
[mm]
[mm]
[mm]
[mm]
[mm]
1 CX V
1685
1080
2150
-
-
2 CX V
1745
1080
2150
-
-
3 CX V
1800
1080
2150
-
-
4 CX V
1800
1400
2150
-
-
5 CX V
1845
1440
2400
-
-
6 CX V
2055
1750
800
1540
800
7 CX V
2095
2100
800
1540
800
The product can be lifted with a forklift or a crane using slings.
When lifting with a forklift, the length of the fork must be greater than the length or width of the product (depending on the product version). The
condensate pipes must be protected against damage.
The inner legs of the product of AmberAir Compact 1-5 CX V versions are covered with protection to prevent damage of the condensate drainage
pipes. Therefore, when lifting with a forklift, the width of the fork must be greater than the condensate protection width.