P a g e

 | 

 

 

 

 

12-32-0000 32 PORT INPUT EXPANSION MODULE 

 

Product Manual 

 

 

 

Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand 

 

     April 2017 

Indicators 

 

 

There are 6 indicators on the top panel consisting of: 

 

 

 

Purpose 

Label 

Description 

System Error 

ERROR 

The RED error LED will indicate when there is a system error. A 
flashing RED LED indicates the unit cannot communicate with 
the transmitter or an adjacent input module, or if the 
message buffer is full 

Upstream 
Receive Data 

RX DATA 

This GREEN LED flashes to indicate serial data is being 
received from an upstream device 

Upstream 
Transmit Data 

TX DATA 

This RED LED flashes to indicate serial data is being 
transmitted to an upstream device 

Power 
Indicator 

SYSTEM 

The GREEN power LED, which normally flashes ON once per 
second to indicate healthy micro-controller operation. After 
a de-bounce period, the green LED will flash rapidly if the low 
supply detector is activated 

Downstream 
Receive Data 

RX DATA 

This GREEN LED flashes to indicate serial data is being 
received from a downstream device 

Downstream 
Transmit Data 

TX DATA 

This RED LED flashes to indicate serial data is being 
transmitted to a downstream device 

 

 

 

Содержание 12-32-0000

Страница 1: ...Copyright 2017 Sea Air and Land Communications Ltd All rights reserved 12 32 0000 32 Port Input Expansion Module PRODUCT MANUAL Version 1 00 April 2017...

Страница 2: ...ocumentation This document is designed to familiarise you with Salcom products and guide you through the hardware configuration installation and overall system management Salcom is an environmentally...

Страница 3: ...t pre paid Please include a description of the fault to assist with prompt return Any unauthorised alterations or repairs will invalidate the warranty All information provided in this document is care...

Страница 4: ...s as required A simple LCD provides indication of current inputs states and system messages LEDs provide indication of system health upstream and downstream serial port activity When a message is gene...

Страница 5: ...allation and Connections The power supply is connected via P1 green power connector to 13 8 Volts and Ground The supply input is protected against reversed connection S1 Upstream Connections S2 Downst...

Страница 6: ...e Data RX DATA This GREEN LED flashes to indicate serial data is being received from an upstream device Upstream Transmit Data TX DATA This RED LED flashes to indicate serial data is being transmitted...

Страница 7: ...without acknowledging so that input modules may be connected to a PC or unit that does not support Salcom protocol but this is not advised since messages may be lost When configured to wait for acknow...

Страница 8: ...y message Watchdog External Discrete Inputs An action can be initiated from the 32 external inputs with an input transition to LOW connection to GND and or HIGH input floating or connection to 3 5v Lo...

Страница 9: ...T EXPANSION MODULE Product Manual Sea Air and land Communications Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand April 2017 Connecting Multiple Input Expansion Modules System Configurat...

Страница 10: ...land Communications Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand April 2017 Error Codes Error Code Description ER2 NOACK The downstream device failed to acknowledge the last sent mes...

Страница 11: ...eck No illumination of Green LED Bad power supply connection Input activated but no message sent PSD configuration incorrect No RS232 serial communication Comport connections baud rate 9600 no parity...

Страница 12: ...e that the 12 32 PSD has the correct com port selected Once correctly configured perform the following 1 Press connect The status at the bottom of the 12 32 PSD will indicate if successfully connected...

Страница 13: ...r both a high and low state Input parameters may be configured as follows Pager type Numeric or Alpha numeric Tone only pagers are supported by ensuring that the message field is left blank Beep Level...

Страница 14: ...will occur the input is assumed to be low on startup the transition to high resulting in message being transmitted if enabled and the input is in the high state PSD General configuration Selecting Opt...

Страница 15: ...hristchurch 8024 New Zealand April 2017 Technical Specification Power Supply 11 5 V to 15 2 V nom 13 8 V Input Current 40mA approx Messaging Protocol SALCOM proprietary paging protocol Serial input ou...

Страница 16: ...r and land Communications Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand April 2017 How to Contact Us Sea Air and Land Communications Salcom Ltd 10 Vanadium Place Addington Christchurch...

Отзывы: